EN
22
23
11/ Association with an alarm control unit
13/ Your remote control is lost or not functioning
These procedures are used to set the motor to association wait mode for a new
control unit (Tyxia 1703, 1712, TYDOM, etc.) when the remote control of the
relevant motor has been lost or is out of order.
13.1 From a new remote control
Switch off the motor power supply, wait 10 seconds, then switch the motor back on.
Other motors are connected to the same circuit breaker and are not concerned
by the change of remote control.
After reactivating, operate each of them once (using their master remote control)
before associating the new remote control.
From a new remote control:
- Press the B button on the front panel of the remote control twice, until the LED
flashes orange.
- Press
and
for 3 seconds until the flashing stops.
The motor (receiver) has not been associated before
- Associate the new remote control to the motor (see § 3.1).
13.2 From the push button
If a push button connects the motor to a local control, you can set the motor to
association wait mode.
To do this:
• Switch off the mains
• Wait for 10 seconds
On the push button:
• Press and hold the button for 3 seconds while switching the mains back on
• Release the push button when the motor gives an acknowledgement confirming
that the motor is in association wait mode (it only remains in association mode for 2
minutes)
12.2
Associating an Efficacité RE2 radio motor
12.3
Defining the motor’s operating mode
... ... ...
>5s
Bip
ON OFF
> 3s
x 1
x 2
On the motor remote control,
press the
button for more
than 3 seconds until the motor
operates briefly.
Set the alarm control unit to Maintenance mode, open it and
then briefly press button 2 of the control unit.
The motor briefly starts twice.
Close the control unit.
> 3s
Operation of modes 1 and 2:
When surveillance is activated, the shutter will close fully.
❶
Press button B on the front panel of
the remote control twice, until the LED
flashes orange.
❷
Then, press the
button for ~3
seconds until the motor is activated
briefly.
The motor is activated once: Mode 1
The motor is activated twice: Mode 2
The motor is activated 3 times: Mode 3
Repeat operations
❶
and
❷
to change
from one mode to another.
The motor will be
activated
briefly.
Alarm
activation
Alarm stop
Mode 1 (by default)
The shutter closes
The shutter remains in
position
Mode 2
The shutter closes
The shutter opens
Mode 3
The shutter remains in
position
The shutter remains in
position
When the system is operated with a push button, the motor works in sequence
(press once: up... press a 2nd time: stop... press a 3rd time: down... press a 4th time:
stop... press a 5th time: up...).
Only for xRP motors
Pressing and holding the push button (> 2 seconds) causes the shutter to operate at
slow speed («Silence» mode).
14/ Operation with a push button