11/  Association with an alarm control unit 

13/  Your remote control is lost or not functioning

These procedures are used to set the motor to association wait mode for a new 

control unit (Tyxia 1703, 1712, TYDOM, etc.) when the remote control of the 

relevant motor has been lost or is out of order.

13.1  From a new remote control

Switch off the motor power supply, wait 10 seconds, then switch the motor back on.

Other motors are connected to the same circuit breaker and are not concerned 
by the change of remote control.

After reactivating, operate each of them once (using their master remote control) 
before associating the new remote control.

From a new remote control:

- Press the B button on the front panel of the remote control twice, until the LED 

flashes orange.

- Press 

 and 

 for 3 seconds until the flashing stops.

 

The motor (receiver) has not been associated before

- Associate the new remote control to the motor (see § 3.1).

13.2  From the push button

If a push button connects the motor to a local control, you can set the motor to 
association wait mode.
To do this:
• Switch off the mains 

• Wait for 10 seconds

On the push button:

• Press and hold the button for 3 seconds while switching the mains back on

• Release the push button when the motor gives an acknowledgement confirming 

that the motor is in association wait mode (it only remains in association mode for 2 
minutes)

12.2 

Associating an Efficacité RE2 radio motor

12.3 

Defining the motor’s operating mode

 

... ... ...

>5s

Bip

ON OFF

> 3s

x 1

x 2

On the motor remote control, 
press the  

 button for more 

than 3 seconds until the motor 

operates briefly. 

Set the alarm control unit to Maintenance mode, open it and 

then briefly press button 2 of the control unit.
The motor briefly starts twice.

Close the control unit.

> 3s

Operation of modes 1 and 2: 
When surveillance is activated, the shutter will close fully.

Press  button B on the front panel of 

the remote control twice, until the LED 

flashes orange.

 Then, press the 

 button for ~3 

seconds until the motor is activated 

briefly.

The motor is activated once: Mode 1
The motor is activated twice: Mode 2
The motor is activated 3 times: Mode 3

Repeat operations 

 and 

  to change 

from one mode to another.

The motor will be 

activated

briefly.

                   

Alarm 

activation

Alarm stop

Mode 1 (by default)

The shutter closes

The shutter remains in 

position

Mode 2

The shutter closes

The shutter opens

Mode 3

The shutter remains in 

position

The shutter remains in 

position

When the system is operated with a push button, the motor works in sequence 
(press once: up... press a 2nd time: stop... press a 3rd time: down... press a 4th time: 
stop... press a 5th time: up...).

Only for xRP motors

Pressing and holding the push button (> 2 seconds) causes the shutter to operate at 
slow speed («Silence» mode).

14/  Operation with a push button 

Summary of Contents for TYMOOV 10RE2

Page 1: ...EN Wireless Tubular Motor range TYMOOV radio xRP2 DxRP2 xRE2 ...

Page 2: ...nd that the risks involved have been understood Children must not play with the device Cleaning and maintenance by the user must not be carried out by unsupervised children The operating device of an unlockable switch must be in direct view of the driven part but kept away from the moving parts It must be installed at a height of at least 1 5 m The fixed control devices must be installed in a visi...

Page 3: ...type A plate on the motor indicates the nominal torque and operating time TYMOOV xRP2 DxRP2 or xRE2 tubular motors are designed to operate intermittently 4 minutes of continuous operation They are electronically protected to prevent overheating If there is a thermal shutdown the motor will operate again after a time period of approximately 30 seconds To operate again for 4 minutes the motor must h...

Page 4: ...g the first remote control to a motor 11 4 2 Setting stops 12 5 Modifying stops 16 6 Associating another transmitter 16 7 Linking a smoke detector directly to the motor 17 8 Grouped command 17 9 Obstacle detection 18 9 1 Setting of the obstacle detection type 18 9 2 Adjustment of the sensitivity of obstacle detection for Basic detection only 19 10 Remove one or several associations 19 10 1 Remove ...

Page 5: ...ling L Total length TYMOOV 6 10 and 20 Nm 395 mm 424 mm Tube L length for drilling wheel attachment by screws or rivet 2 3 Motor head position The motor head must be positioned on the mount such that the cable outlet is in the lower part when seen horizontally 2 4 Attaching the motor to the mount Push the tube motor A onto the mount B until it locks into place click 8 NO 8 NO 8 NO 4 OK 4 OK 4 OK C...

Page 6: ...associate The corresponding shutter will be activated briefly once Once the motor has been found press briefly After a few seconds the shutter will be activated briefly twice to confirm the association To exit association mode hold for 3 seconds You will then be able to pass to Set stops mode 3s The electrical wiring must comply with EN IEC and national institute standards for installation e g NF ...

Page 7: ...n slightly so that there is no force on the shutter x 1 Upper physical stop Lower physical stop Stop on shutter blade Press the button briefly until the shutter reaches the upper stop The stop position will now be automatically set The motor will be activated briefly The stop position will now be automatically set The motor will be activated twice Automatic upper stop Automatic lower stop The stop...

Page 8: ...lease the and buttons at the same time To scroll step by step briefly press then release the and buttons at the same time Press button B on the front panel of the remote control until the LED flashes green Then press and hold the button for 3 seconds until the motor is activated briefly The upper manual stop will now be set The motor will be activated briefly Press the button to move the shutter t...

Page 9: ...he opening of roller shutters in the event that smoke is detected Motor type Linking to a wireless smoke detector TYMOOV xRP2 and DxRP2 Wireless smoke detector directly linked to the motor TYMOOV xRE2 Version S02 04 00 Wireless smoke detector directly linked to the motor TYMOOV xRE2 Version S02 04 00 Only by linking your motor and the wireless smoke detector to a TYXAL alarm system To find out the...

Page 10: ... DxRP2 motors you have a choice between two detection modes Protect Detection default mode more efficient obstacle detection preventing the apron from unwinding in the casing Basic Detection detection of obstacles with unwinding of the apron in the casing Repeat the operations above to switch between modes The Radio Efficacité xRE2 motor only has Basic obstacle detection 3s x 2 Press button B on t...

Page 11: ...unit to Maintenance mode then to Add product mode Set the alarm control unit to Add product mode Associate the intruder mode with the alarm control unit Press button B on the front panel of the remote control twice until the LED flashes orange Then press and hold the button for 3 seconds until the motor is activated briefly The alarm control unit will beep The alarm control unit will beep The roll...

Page 12: ...t the motor is in association wait mode it only remains in association mode for 2 minutes 12 2 Associating an Efficacité RE2 radio motor 12 3 Defining the motor s operating mode 5s Bip ON OFF 3s x 1 x 2 On the motor remote control press the button for more than 3 seconds until the motor operates briefly Set the alarm control unit to Maintenance mode open it and then briefly press button 2 of the c...

Page 13: ... stop then a manual stop Press the push button 2 seconds so that the motor operates in the up or down direction When the motor detects the 1st stop upper or lower then the motor operates once 2s x 1 OR x 3 2s 2s x 2 2s x 2 STOP OR Press the push button 2 seconds so that the motor operates in the opposite direction Briefly press the push button to stop the motor at the position corresponding to the...

Page 14: ...2 manual stops x 3 2s 2s x 2 2s x 2 STOP OR Press the push button 2 seconds so that the motor operates in the up or down direction Briefly press the push button to stop the motor at the position corresponding to the manual stop Then if the shutter is down briefly press the push button 3 times then press and hold the push button 2 seconds if the shutter is up briefly press the push button 2 times t...

Page 15: ...n on the remote control 3 times The motor operates twice x 2 x 1 TYMOOV xRP2 and DxRP2 software version S02 04 00 and higher The motor operates once x 2 x 1 TYMOOV xRE2 software version S02 04 00 and higher The motor does not respond TYMOOV xRE2 or xRP2 or DxRP2 software version S02 04 00 See label on the motor 17 Troubleshooting Press the push button once to move the shutter down or up Switch off...

Page 16: ...www deltadore com 05 21 ...

Reviews: