background image

- 8 -

- 9 -

EN

1. Presentation

2. Location

Locations to avoid 

Do not install the detector:
• Within a metre from vents for heating, cooling or circulating air. 

  The smoke could be blown away from the detector or be diluted.
• In a place where the temperature could drop beneath 0°C or rise above 

+50°C; risk of detector not working correctly.
• In a place where there is a risk of condensation. Bathrooms and laundry 

rooms are not recommended.
• Places where smoke could gather (kitchen or poorly ventilated garage) and 

cause false alarms.
• In a place that is excessively dusty.
Do not install in non-converted attics.

Additional installation recommendations, as well as the "Mandatory 
Performance Declaration" for this equipment are available in the 
product fi le for 

DFR TYXAL+

 on our website www.deltadore.com

Material manufactured by SHD BP10809 under reference DOF79R.

The detector can be associated with a DELTA DORE wireless X3D alarm and 

control system.

Functional check and maintenance: 

You must check that your detector is functional once a 

month or after each battery change.

Pressing the “test” button on the case for a few seconds 

will light up the LED and the detector will emit 2 beeps.

Quick fl ashing from the detector means that it has 

switched to pre-alarm mode (multiple readings).

If the detector’s sensors confi rms the presence of smoke, 

the alarm will be activated.

Do not try to trigger the alarm any other way (using a lighter, etc.) because you 

could damage the detector or even start a fi re.

Your detector has been designed to require the minimum maintenance possi-

ble. However, some simple actions need to be performed once a year. 

After having removed the detector:

• Clean the cracks in the detector (located on the side) with a vacuum clean-

er, using a soft brush or a vacuum cleaner accessory.
• Use a slightly damp cloth to clean the outside of the case.
• Do not blow on the detector to avoid lifting dust.

4

OK

2

1

3

>3s

It is recommended that the detector be replaced after 10 years.

2. Location

20 cm

90 cm

15-25

cm

60 cm

• The detector should preferentially be at-

tached to the ceiling in the middle of the room. 

Otherwise, attach it more than 20cm from any 

obstacle (partition wall, beam, etc.) and over 

60cm from any room corner.

• If this is impossible, attach the detector to 

the wall at a distance of between 15 and 25cm 

from the ceiling.

• In the case of an angled ceiling, attach the 

detector at a location between 20 and 90 cm 

vertically below the highest point.

In the home:

In the room:

Recommended locations:

• For enhanced protection:

- Place a detector in each room, avert using listed places to avoid.

• For basic protection:

- Place a detector on each fl oor.

- Place a detector close to sleeping areas 

  (for example, in the corridor leading to rooms; in the case

   of a long corridor > 10m, place 1 detector at each end).

- Place a detector in each bedroom occupied by a smoker.

Flat

House

Dining

room

Kitchen

Bedroom

Smoker 
bedroom

Lounge

Bedroom

Basic protection

Enhanced protection

Bedroom

Bedroom

Lounge

Kitchen

Basement

Corridor

Reviews: