- 38 -
Test the door/window magnetic contacts
Whenever the system is activated or deactivated,
the alarm control unit sends a series of beeps, indicating that an
event (opening detection in this case) has
occurred.
To clear the event:
see previous page.
8.2 Test on a specific product
If you want to test a specific product, you must:
- deactivate the system
- press the button of the relevant product:
Products
Signalling
Motion detectors (DMB, DMBD
TYXAL+)
1 flash when p 1 flash for confirmation by alarm control unit.
Curtain motion detector
(DMDR TYXAL+)
1 beep when p 1 beep for confirmation by alarm control unit.
Door/window magnetic con-
tact
(DO TYXAL+)
1 flash when p 1 flash for confirmation by alarm control unit.
Door/window magnetic con-
tacts
(MDO, DOI PVC TYXAL+)
1 flash when pressed
Technical detectors
(DU, DOS, DF, DCP TYXAL+)
1 beep when pressed
Smoke detector
(DFR TYXAL+)
1 alarm cycle triggered
Telephone transmitters
(TTRTC, TTGSM TYXAL+)
1 beep when p 1 beep for confirmation by alarm control unit.
If the detector is in delayed triggering mode,
the control unit will only set off the alarm after
45 seconds.
If the alarm control unit does not sound, take another
look at the installation or association of the detector.
OFF
ON
Beep
8. Testing your installation
Stop the
alarm
Beep,
Beep
Alarm control unit
sets off the siren
Open the entry
to test
Wait for the exit timer
(up to 90 seconds)
All the entries protected by
a door/window magnetic
contact are closed.