Page 2: ...ren function immedi ately warns the neighbours by triggering both a phone call via a transmitter as well as the sound of the associat ed sirens Maintenance mode the Maintenance mode is reserved for the installer It is used to perform the activation main tenance and diagnostic operations The system must be off to access this mode The alarm control unit is switched to Maintenance mode with a keypad ...

Page 3: ...ggering of an SOS with siren 14 3 6 Clearing defects 14 3 7 Disabling audible beeps for the button 14 3 8 Changing your access code 15 4 Use with the badge reader 16 4 1 Configuring buttons 1 and 2 16 4 2 Activating the system 16 4 3 Deactivating the system 17 4 4 Manual override 17 4 5 Triggering of a discreet SOS alarm 18 4 6 Triggering of an SOS with siren 18 4 7 Clearing defects 18 5 Use with ...

Page 4: ...alert to relatives only with a GSM transmitter 34 7 14 SIM card only with a GSM transmitter 34 7 15 Zone management 35 7 16 Door chime function 35 7 17 Changing your access code 36 8 Testing your installation 37 8 1 Test under operating conditions 37 8 2 Test on a specific product 38 9 Activating Deactivating a product 39 9 1 Using your touch screen keypad 39 9 2 Using your telephone transmitter 3...

Page 5: ... unit and or by an associated siren indoor or outdoor and or using an associated transmitter to another telephone or a remote monitoring operator The system is fully battery operated The battery life is 10 years Your alarm and home automation system can be controlled remotely up to 5 control systems 4 scenarios 1 heating channel from a telephone transmitter or the TYDOM application see transmitter...

Page 6: ...floor during the day when you are in the ground floor zone Likewise at night the ground floor is protected when you are on the first floor You can also use a zone outside of your home to protect your yard or garden for example This zone is called pre alarm zone 1 3 Exit timer You are leaving the home When the system is activated you have an exit timer up to 90 seconds After this time the alarm con...

Page 7: ... er Heating and Cooling or Control system applications Examples You want to switch off the heating if a window is opened The door window magnetic contacts can be associated for example with an energy manager You want to delay the alarms status of the system or the operations for activat ing or deactivating the system via an offset lighting You can associate a receiver for control systems You want ...

Page 8: ...S Transmitter call without audible signalling Mode C Triggering of an SOS with siren SOS Transmitter call audible alert Mode D Pulse control of a control system or lighting x1 Mode E ON OFF ON OFF control for lighting or roller shutters Buttons 1 and 2 can be programmed separately Mode A by default There are 5 modes A B C D or E Only 2 of them can be combined e g Mode A with Mode D refer to the ta...

Page 9: ...ss OFF The LED changes from red to green to confirm the action Shutdown by zone 1 or 2 Example zone 1 floor Press the 1 button then OFF The LED changes from red to green to confirm the action OK ON OK ON 1 Beep Beep OK OK 1 OFF OFF Depending on the installation settings the alarm control unit will or will not beep to confirm the activation or deactivation actions The 1 and or 2 buttons must be con...

Page 10: ...call cycle from the transmitter to the programmed numbers starting with the 1st number an audible signal from an associated siren The LED changes from red to green to confirm the action Press OFF to stop an emergency alarm with siren in progress ON 1 Activation denied e g open entry Beep beep beep ON ON 5s OK 1 2 2 Use with the remote control For example this function is used to activate the syste...

Page 11: ...u can clear defects by using the remote control Press and hold the OFF button for 5 seconds The LED changes from red to green to confirm the action The alarm control unit emits a series of beeps stops then emits one more beep 2 8 Controlling a control system Mode D Pulse control Press the 1 or 2 button The LED changes from red to green Mode E On Off control Press the 1 or 2 button then ON OFF or O...

Page 12: ...2 Deactivating the system Complete shutdown Ê Enter your access code Ë Press The LED changes from red to green to confirm the action Shutdown by zone Example zone 2 Ê Enter your access code Ë Press the button then then The LED changes from red to green to confirm the action OK ON 1 2 OK ON 1 2 LED Activation SOS with siren button Shutdown Zone button OK OFF 1 2 OK OFF 1 2 Wrong code entered The ke...

Page 13: ...ress code 023456 The LED changes from red to green to confirm the action The alarm control unit emits a BEEP The telephone transmitter calls from the 3rd number programmed The 1st and 2nd numbers are not called for the discreet SOS ON 1 5s ON ON 1 2 OK SOS 1 1 Access code Access code Duress code Duress code For example this function is used to activate the system even if an entry remains open or i...

Page 14: ...intruder detection product de fect open entry etc can be cleared so as not to be signalled by the control unit The system must be off If you do not have a touch screen keypad you can clear defects by using the simple keypad Ê Enter your access code Ë Press and hold the button for 5 seconds The LED changes from red to green to confirm the action The alarm control unit emits a series of beeps stops ...

Page 15: ...rol actions and a few configuration actions You can change it Restricted code you can restrict access to your home by a code that gives access only to the ON and OFF controls of the zones with which it is associated e g maintenance personnel delivery etc The access codes 6 digits are recorded in the alarm control unit You configure the access codes once with the touch screen keypad and the other p...

Page 16: ... or C Mode A by default It is only possible to mix two of them e g Mode A with Mode B see table opposite 4 2 Activating the system Complete activation Ê Press The red LED switches on Ë Place your badge on the detection zone before 5 seconds The LED changes from red to green to confirm the action The alarm control unit emits a BEEP Operation by zone 1 or 2 Example zone 1 floor Ê Press the button th...

Page 17: ... It emits a series of beeps to warn the user On the badge reader the LED flashes red Ë Confirm a second time by pressing ON badge within 5 seconds after first pressing the button The LED changes from red to green to confirm the action OK 5s 5s OK 1 2 1 2 ON 1 5s ON ON 1 2 Depending on the installation settings the alarm control unit will or will not emit beeps to confirm the activation or deacti v...

Page 18: ...eeps or a refusal to switch on These events intruder detection product defect open entry etc can be cleared so as not to be signalled by the control unit The system must be off If you do not have a touch screen keypad you can clear defects by using the badge reader Press the button for 5 seconds then place the badge on the detection zone The LED changes from red to green to confirm the action The ...

Page 19: ... the system Complete shutdown Ê Enter your access code Ë Press OFF The LED changes from red to green to confirm the action Shutdown by zone Example zone 2 Ê Enter your access code Ë Press then OFF The LED changes from red to green to confirm the action OK 1 2 OK 1 2 3 Activate ON Shutdown OFF LED OK 1 2 OK 1 2 3 Wrong code entered The keypad is locked for 90 seconds after five attempts with the wr...

Page 20: ... The LED changes from red to green to confirm the action The alarm control unit emits a BEEP The telephone transmitter calls from the 3rd number programmed The 1st and 2nd numbers are not called for the discreet SOS 1 2 5s 1 2 3 4 OK SOS 1 1 For example this function is used to activate the system even if an entry remains open or if a product shows a defect dead battery etc 5 Use with your outdoor...

Page 21: ...rol is of the hold type lighting Press the button to activate Press the button to shut down The control is of the roller shutter type Press the button to control the raise operation Press the button to control the lower operation Press the button to stop accessible without access code Type of control system Pulse e g gate ON OFF channel 1 ON OFF channel 2 Hold e g lighting ON OFF Roller shutter Ra...

Page 22: ...fo Settings My house ON System fully activated 25 11 15 12 48 Info Settings OFF My house System fully shut down 25 11 15 12 48 Info Settings Floor ON ON At least one zone of the system is on 25 11 15 12 48 Info Settings Floor ON OFF At least one zone of the system is off Info Settings Maintenance 25 11 15 12 48 The system is in maintenance mode It cannot be activated Menu reserved for the installe...

Page 23: ... My house 1 tamper alarm 2 events not cleared Clear defects Histories Info 2 products deactivat 1 open entry Ok Back 2 defects Battery defect detector op living room 1 ground floor Acquitter Back Battery defect motion detector kitchen ground floor Acquitter Back Clear all defects Yes No Products deactivat Back DO lounge DO living room Open entry detector op living room window zone 2 Back Tamper al...

Page 24: ...ton to activate the keypad Ë Enter your access code and press OK Ì To reach the zone press the arrows Í Press OFF 25 11 15 12 48 SOS Settings OFF Enter your code 25 11 15 12 48 Info OK Settings OFF My house 25 11 15 12 48 Info Settings Floor ON OFF 25 11 15 12 48 Info Settings Floor ON ON ON 1 2 3 4 25 11 15 12 48 SOS Settings Enter your code 25 11 15 12 48 Info Settings My house OFF ON OFF 1 2 25...

Page 25: ...latives that you are in a situation of distress It also sets off the sirens with a specific tone Ê Press the button to activate the keypad Ë Press SOS A 10 second countdown starts before the SOS is triggered a call cycle from the transmitter to the programmed numbers starting with the 1st number an audible signal from an associated siren To stop an emergency alarm with siren in progress enter the ...

Page 26: ...ck Summer Winter No Ok Back Time format 24H Ok Back Time format am pm Ok Back Date format JJ MM AA Ok Back Date format MM DD YY Ok Back Access code XXXXXX Ok SOS 1 2 3 5 6 4 25 11 14 12 48 SOS Settings OFF Enter your code Info Settings My house OFF 25 11 14 12 48 Languages Deutsch Español Italian English Ok Back Nederlands Polski Settings Ok Back Use Clock Languages Access code XXXXXX Ok SOS 1 2 3...

Page 27: ...vate deactivate Ok Programming Back Copy the day Programming Activate deactivate Ok Programming Back Copy the day Affect zone Programming Ok Copy the day Back Affect zone Activate deactivate Settings Ok Back Languages Download Programming 4 5 6 3 2 Access code XXXXXX Ok SOS 1 25 11 15 12 48 SOS Settings OFF Enter your code Info Settings My house OFF 25 11 15 12 48 Programming Deactivate Ok Back Th...

Page 28: ... 4 4 Screen brightness 4 Button lighting 4 Button beeps 4 Display the status of the monitoring 4 Siren sound levels 4 4 4 Warning beep sound levels 4 4 4 Call numbers 4 4 Incoming calls 4 SIM card 4 SMS alert to rela tives 1 4 4 4 Voice SMS distribu tion option 2 4 Auto attendant 4 4 1 Example a child comes home and deactivates the system via the remote control or badge reader the GSM telephone tr...

Page 29: ... or outdoor gate DFR Wireless smoke detector DMB Motion detector DMD Dual technology motion detector DMV Video motion detector DO Door window magnetic contact DOI Integrated door window magnetic contact DOS Floor detector DU Universal detector DVR Roller shutter detector GSM GSM transmitter LB Badge reader MDO Door window magnetic micro contact REP Repeater PSTN PSTN transmitter Ro Rollia motor SE...

Page 30: ...OK 7 8 Screen brightness Ê Enter the user code e g 456789 and confirm with OK Ë Press Settings select the menu Use Products Configure then confirm with OK Ì Select the touch screen keypad from the list of products by clicking on Browse then confirm with OK Í Select the Brightness menu then set the value using the and arrows Î Confirm with OK 4 5 Keypad Brightness Ok Back Button beeps Button lighti...

Page 31: ...nfirm with OK Ò You can test the sound setting by confirming with Yes The control unit emits beeps briefly Use Zones Door chime Ok Products Back Configure Browse Back Press the button of the product Configure Products Ok Activate deactivate Back Settings Clock Languages Ok Back Use Access code XXXXXX Ok SOS or Browse Configure Ok Back CS 0 54 89 SI 0 48 24 1 2 3 SEF 0 48 23 4 8 9 5 6 7 Control uni...

Page 32: ...1 Ok 0 Back Distribution option Tel no 1 Ok Voice Back Distribution option Tel no 1 Ok SMS Back Use Zones Door chime Ok Produits Back Configure Browse Back product Press the button of the Products Ok Activate deactivate Back Configure Settings Clock Languages Ok Back Use Access code XXXXXX Ok SOS or Browse 1 3 2 25 11 14 12 48 SOS Settings OFF Enter your code Info Settings My home OFF 25 11 14 12 ...

Page 33: ...uide or select it from the list of products by clicking on Browse then confirm with OK Í Select the Auto attendant menu then Activate or Deactivate Î then confirm with OK 4 5 PSTN transmitter Ok Back Incoming calls Alarm control unit monitoring Auto attendant Activate Ok Back Auto attendant Auto attendant Deactivate Ok Back Incoming calls are calls made from a telephone to your telephone transmitt...

Page 34: ...ts by clicking on Browse then confirm with OK Í Select the menu SIM card then confirm with OK Î Enter the parameters of the SIM card Enter the PIN code Enter the PUK code Confirm with OK 4 5 GSM transmitter Remote monitoring SIM card Auto attendant Alarm control unit monitoring Ok Back SMS alert to relatives SMS alert to relatives Ok Select 4 5 GSM transmitter SMS alert to relatives Ok Back SIM ca...

Page 35: ...ate deactivate Scullery Workshop Bath shower 4 Name zone Ok Personalise Reception Back Settings Clock Languages Ok Back Use Use Door chime Ok Products Back Access code XXXXXX Ok SOS 1 2 3 Zones Ok Back Configure Zone selection Zone 3 Ok Zone 1 Zone 2 Back Configure zone Ok Back Name zone Zones 25 11 14 12 48 SOS Settings OFF Enter your code Info Settings My house OFF 25 11 14 12 48 For naming the ...

Page 36: ...void codes such as date of birth or series of easy to reproduce digits 222222 234567 etc You have 10 user or restricted codes 6 digits The user code enables the control actions and a few configuration actions You can change it Restricted code you can restrict access to your home by a code that gives access only to the ON and OFF controls of the zones with which it is associated e g maintenance per...

Page 37: ...ccurred You can view this on a touch screen keypad To clear the event Press and hold the remote control s OFF button for 5 seconds The control unit emits beeps when pressed then a series of beeps after 5 sec onds The LED changes to green on the remote control Release The event is cleared The event can also be cleared through the Info menu of a touch screen key pad If the detector is in delayed tri...

Page 38: ... con tact DO TYXAL 1 flash when pressed 1 flash for confirmation by alarm control unit Door window magnetic con tacts MDO DOI PVC TYXAL 1 flash when pressed Technical detectors DU DOS DF DCP TYXAL 1 beep when pressed Smoke detector DFR TYXAL 1 alarm cycle triggered Telephone transmitters TTRTC TTGSM TYXAL 1 beep when pressed 1 beep for confirmation by alarm control unit If the detector is in delay...

Page 39: ... chime Ok Products Back Settings Clock Languages Ok Back Use Access code XXXXXX Ok SOS 1 2 25 11 14 12 48 SOS Settings OFF Enter your code Info Settings My house OFF 25 11 14 12 48 A product can be deactivated locally with a touch screen keypad or remotely via a telephone transmitter e g a detector that gen erates intrusions because of an incorrectly closed window When a product is deactivated som...

Page 40: ...or off command etc The events on the touch screen keypad must be viewed Info menu Beep beep beep beep beep Action confirmed Association removal test activation or deactivation com mand total or by zone etc Short beep Intruder alarm For any intruder detection For any sabotage attempt tamper alarm Intrusion siren Smoke alarm If smoke or any other fumes due to a fire hazard are detect ed Specific fir...

Page 41: ... a cool preferably 30 C dry well ventilated place Keep away from any sources of moisture heat open flames Keep the batteries in the original packaging until they are used Do not store in bulk Do not exert any force that may cause a deformation 2 Handling Do not mix batteries of different models or different brands Do not mix new and used batteries Do not heat or weld directly Do not disassemble Li...

Page 42: ... keypad are not in the delayed triggering position Whenever the system detects something or someone passing in front of a motion detector or opening of a protected entry the detector LED starts flashing The batteries must be changed There is a tamper alarm problem on one of the installa tion s products Check the tamper alarms The batteries of one of the products are dead A door or window remained ...