background image

EN

4

5

Recommendations

- Cables going through a metal wall must be protected and isolated by 

a sleeve. 
The TYMOOV xRP/DxRP or xRE cable can be disassembled.

- If the power cable is damaged, it must be replaced by the 

manufacturer, after-sales service or similarly qualified personnel in 
order to prevent hazards.

- The motor must be chosen according to the requirements of the load 

bearing support. See our charts for selecting the motor according to 
the shutter type. A plate on the motor indicates the nominal torque 
and operating time.

- TYMOOV xRP/DxRP or xRE tubular motors are designed to 

operate intermittently (4 minutes of continuous operation). They 
are electronically protected to prevent overheating. If there is a 
thermal shutdown, the motor will operate again after a time period 
of approximately 30 seconds. To operate again for 4 minutes, the 
performance motor must have returned to room temperature.

- If an attempt is made to raise the shutter (for example: intruder test), 

the motor will lower the apron. Caution, your fingers may be caught.

DELTA DORE hereby declares that the motorised systems covered by these 

instructions comply with the essential requirements set out by the Machinery 

Directive 2006/42/EC and the European directive RED 2014/53/EU.

The EU declaration for this equipment is available on request 

from:

Service “Info techniques”

DELTA DORE – 35270 Bonnemain (France)

email: [email protected]

DELTA DORE

35270 - BONNEMAIN - France

[email protected]

CE Declaration

Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this 

document are not binding unless confirmed by our departments.

Summary of Contents for TYMOOV PERFORMANCE DXRP

Page 1: ...FR Gamme de moteurs tubulaires radio birectionnels EN Bidirectional Wireless Tubular Motor range DE Produktreihe Rohrmotor bidirektionale Funktechnologie TYMOOV PERFORMANCE XRP DXRP EFFICACITE XRE...

Page 2: ...a visible area Frequently check the equipment to detect any imbalances or signs of wear or damage to cables and springs Do not use the device when repairs or adjustments are required Preliminary eleme...

Page 3: ...the motor will operate again after a time period of approximately 30 seconds To operate again for 4 minutes the performance motor must have returned to room temperature If an attempt is made to raise...

Page 4: ...ops 12 4 Modifying stops 16 5 Associating another transmitter 16 6 Associating a smoke detector 17 7 Grouped command 17 8 Remove one or several associations 18 8 1 Remove an association 18 8 2 Remove...

Page 5: ...Length for drilling L Total length TYMOOV 10 Nm and 20 Nm 395 mm 422 mm TYMOOV 30 Nm 455 mm 482 mm 1 2 Crown Motor head Wheel Tube L length for drilling wheel attachment by screws or rivet 1 3 Motor h...

Page 6: ...ctivated once Once the motor has been found press briefly After a few seconds the shutter will be activated twice to confirm the association To exit association mode hold for 3 seconds You will then b...

Page 7: ...g 2 automatic stops It is possible that the shutter will move in the opposite direction to the button you press If that is the case you can reverse the direction by pressing button B on the front pane...

Page 8: ...position of the second stop e g lower manual stop The stops are now set Exit the settings mode Press the button until the shutter is in the required position then press to stop it Press the button un...

Page 9: ...d buttons at the same time for more than 3 seconds until the LED comes on The motor will briefly be activated twice You want to control the opening of roller shutters if smoke is detected 6 Associatin...

Page 10: ...until the LED turns on The motor will be activated briefly Once high sensitivity Twice low sensitivity Repeat the operations above to switch between modes Press button B on the front panel of the remo...

Page 11: ...ne the motor s operating mode Intruder surveillance will only be active if the alarm is activated and the shutter closed 12 1 Associating the motor intruder mode with the alarm control unit Set the al...

Page 12: ...rom one mode to another The motor will be activated briefly 13 Your remote control is lost or not functioning Initial condition The lost remote control was only associated with a single motor receiver...

Page 13: ...will move in the opposite direction to the button you press If that is the case you can reverse the direction by briefly pressing button B on the front panel of the remote control until the LED flashe...

Page 14: ...www deltadore com...

Reviews: