Once the dehumidifying function has been selected, the fan
speed cannot be changed. The appliance will automatically
select the correct  fan mode.

VENTILATION

Adjust the fan speed by pressing the “FAN” (Q) button, as illustra-
ted in the air conditioning function.
Bear in mind that the higher the speed, the greater the volume of
air filtered; by selecting the “Silent” speed, less air is filtered, but
the noise level is low.
“AUTO” function cannot be selected in this mode.
The display will show the fan speed selected.

PROGRAMMING THE TIMER

The timer programs the appliance to switch on and switch off. This
will save electrical energy by optimizing the operating times. 
The timer is set using the b (F) or – (G); these increase and
decrease by one hour at a time, but if pressed for more than 2
seconds will automatically change the time more quickly, up to a
maximum of 24 hours.

How to set the delayed start function 

Connect the appliance to the mains supply and press ON/OFF
button: next, select the required operating mode (temperatu-
re, fan speed etc.) 

Press the ON/OFF button again: the appliance will go into
stand-by mode.

Press the timer button (I): on the display the two central seg-
ments will start to flash.

Set the number of hours after which the appliance should swit-
ch on, by pressing the + or – buttons.

The indicator (L) on the display will continue to flash until the
appliance starts operating.
The appliance can be programmed for up to 24 hours in advance.

How to set the delayed stop function

The appliance can be programmed for delayed stop from any
of the operating modes (air-conditioning/dehumidifying/venti-
lation.

Press the Programmer button (I): on the display the two central
segments will start to flash.

Set the number of hours after which the appliance should swit-
ch off by pressing the + or – buttons.

The indicator (L) on the display will continue to flash until the
appliance switches itself off. It will then go into Stand-by mode.

.

“Silent”

speed

“Min”

speed

“Max”
speed

O p e r a t i o n

GB  8-07-2003  15:32  Pagina 12

Summary of Contents for Pinguino K900

Page 1: ...sonal injury Do not use outdoors Do not use the appliance in ways other than that for which it was intended Do not place the power cable under strain Avoid twisting and or tangling Ensure that the out...

Page 2: ...en transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas losing excess heat and moisture before being discharged again into the room In Pi...

Page 3: ...grill 8 Rating plate 9 Water collection tank 10 Water drain tube 11 Stopper for drain tube 12 Power cord Description of the Accessories 13 Stopper and flange 14 Air exhaust hose 15 Air exhaust attachm...

Page 4: ...Fit the air exhaust hose 14 in its housing 5 at the rear of the appliance as shown in fig 1 If you have a double window use the suckers 16 supplied to keep the panes from opening wide figure 3 Fit the...

Page 5: ...nks to the wing nut it s possible to use the window bracket also for sliding windows Position the hole of the bracket to allow a correct instal lation of the exhaust hose see the following instruction...

Page 6: ...f with the flange stop per 13 N B When operating the appliance with semi per manent installation it is advisable to leave a door slightly ajar even only 1cm to ensure free circulation of air In the wi...

Page 7: ...to failure in following normal safety procedures Replacement of the power cable must be carried out by qualified personnel THE DISPLAY A ON OFF Button B Function Button Air conditioning dehumidifying...

Page 8: ...the temperature selected on the display panel DEHUMIDIFYING FUNCTION This function is ideal for reducing humidity in the atmosphere while avoiding increases or decreases in temperature in between sea...

Page 9: ...n Connect the appliance to the mains supply and press ON OFF button next select the required operating mode temperatu re fan speed etc Press the ON OFF button again the appliance will go into stand by...

Page 10: ...persists call the service centre LOW TEMPERATURE If the machine is operating as an air conditioner or dehumidifier this will prevent the formation of ice The appliance will start up auto matically on...

Page 11: ...e sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest objects on the air conditioning unit Do not obstruct the air intake or outlet Mak...

Page 12: ...ards fig 11 2 Remove the dust filter by detaching it from the external grill BEGIN OF SEASON CHECKS Check that the power cord and plug are undamaged and that the appliance is pro perly earthed The ins...

Page 13: ...tat is set too high air filters are dirty the capacity of the air conditioner is not adequate for the conditions or the dimen sions of the room close the window eliminate source of heat set the thermo...

Page 14: ...g Refrigerating capacity Number of fan speeds 2 silent Max air flow 460 m3 h Dimensions of internal unit width 16 92 430 cm height 31 49 800 cm depth 17 32 440 cm weight 75 lb 33 7 kg Standard conditi...