background image

16

Troubleshooting

PROBLEM

CAUSES

REMEDY

The air-conditioner
does not work

the power is off 

the appliance is not plugged in

Plug it in

The air-conditioner
works only for a
short time

The exhaust hose is twisted

The exhaust hose is blocked

The exhaust hose is bent

Position exhaust hose correctly

Check for obstacles blocking
the exhaust system

Straighten the hose

The air-conditioner
works but does not
cool the room.

a  window is open

there is a source of heat in the room (lamp,
burner etc.) or there are many people in the
room.

the thermostat is set too high

air filters are dirty

the capacity of the air-conditioner is not
adequate for the conditions or the dimen-
sions of the room.

close the window

eliminate source of heat

set the thermostat to a lower
temperature 

clean the filters

clean the filters

Strange odour in the
room

air filters are dirty

Leaking condensa-
te from the unit

appliance incorrectly installed

condensate collection tank is full

see instructions for correct
installation of appliance

Empty the tank

The unit does not work
for about 3 minutes
after turning on the
appliance.

wait for 3 minutes

The safety mechanism has been activated

See paragraph “Self diagnosis” if the following messages appear on the display: FF, HP,  LT,  FT,  PF.

GB  8-07-2003  15:32  Pagina 16

Summary of Contents for Pinguino K900

Page 1: ...sonal injury Do not use outdoors Do not use the appliance in ways other than that for which it was intended Do not place the power cable under strain Avoid twisting and or tangling Ensure that the out...

Page 2: ...en transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas losing excess heat and moisture before being discharged again into the room In Pi...

Page 3: ...grill 8 Rating plate 9 Water collection tank 10 Water drain tube 11 Stopper for drain tube 12 Power cord Description of the Accessories 13 Stopper and flange 14 Air exhaust hose 15 Air exhaust attachm...

Page 4: ...Fit the air exhaust hose 14 in its housing 5 at the rear of the appliance as shown in fig 1 If you have a double window use the suckers 16 supplied to keep the panes from opening wide figure 3 Fit the...

Page 5: ...nks to the wing nut it s possible to use the window bracket also for sliding windows Position the hole of the bracket to allow a correct instal lation of the exhaust hose see the following instruction...

Page 6: ...f with the flange stop per 13 N B When operating the appliance with semi per manent installation it is advisable to leave a door slightly ajar even only 1cm to ensure free circulation of air In the wi...

Page 7: ...to failure in following normal safety procedures Replacement of the power cable must be carried out by qualified personnel THE DISPLAY A ON OFF Button B Function Button Air conditioning dehumidifying...

Page 8: ...the temperature selected on the display panel DEHUMIDIFYING FUNCTION This function is ideal for reducing humidity in the atmosphere while avoiding increases or decreases in temperature in between sea...

Page 9: ...n Connect the appliance to the mains supply and press ON OFF button next select the required operating mode temperatu re fan speed etc Press the ON OFF button again the appliance will go into stand by...

Page 10: ...persists call the service centre LOW TEMPERATURE If the machine is operating as an air conditioner or dehumidifier this will prevent the formation of ice The appliance will start up auto matically on...

Page 11: ...e sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest objects on the air conditioning unit Do not obstruct the air intake or outlet Mak...

Page 12: ...ards fig 11 2 Remove the dust filter by detaching it from the external grill BEGIN OF SEASON CHECKS Check that the power cord and plug are undamaged and that the appliance is pro perly earthed The ins...

Page 13: ...tat is set too high air filters are dirty the capacity of the air conditioner is not adequate for the conditions or the dimen sions of the room close the window eliminate source of heat set the thermo...

Page 14: ...g Refrigerating capacity Number of fan speeds 2 silent Max air flow 460 m3 h Dimensions of internal unit width 16 92 430 cm height 31 49 800 cm depth 17 32 440 cm weight 75 lb 33 7 kg Standard conditi...

Page 15: ...ite to De Longhi America Inc Park 80 West Plaza One 4th floor Saddle Brook NJ 07663 or call Service Tel No 1 888 335 6644 GARANTIE Nous garantissons que tous les appareils lectriques DE LONGHI sont ex...

Reviews: