background image

4

Important Safe-guards

This appliance has been manufactured to cool and de-humidify domestic environments and
should not be used for other purposes.

It is dangerous to alter or modify the unit's characteristics in any way.

The appliance must be installed in conformity with the relevant national legislation.

Should repairs be necessary, contact the nearest authorised Repair Service Centre. Unautho-
rised servicing can be dangerous.

This appliance is to be used by adults only; keep children away from it.

The appliance is not intended for use by young children or infirm persons without supervision.

Young children should be supervised to ensure that they do not play with the appliance.

Always ground the appliance. Have the electrical system checked by a qualified electrician.

Avoid using extension leads with the unit.

Before cleaning or maintenance operations, always unplug the unit from the socket.

Do not pull on or place strain on the power cable when moving the appliance.

The appliance should not be installed where the atmosphere may contain combustible gases,
oil or sulphur, or near heat sources.

If the appliance is utilised in areas where there is no ventilation of air, it is necessary to take pre-
cautions to avoid that the refrigerant gases that may leak from the appliance do not remain
in the room, thereby causing a fire hazard.

Do not rest hot or heavy objects onto the appliance.

Clean the anti-bacterial filters at least once a week.

Avoid using heaters near the unit.

The unit should be transported in a vertical position. If this is not possible secure the unit at an
angle, do not lie horizontally. Before transporting the unit drain the condensation collecting-
tray and tank. Avoid transportation, wait at least 1 hour before switching on the unit.

The packaging materials can be recycled. You are therefore recommended to place them in
the special containers for differentiated waste collection.

•  Keep the unit at least 50 cm away from inflammable substances (alcohol etc) or pressurised

containers (eg. aerosol cans).

The appliance must be used only as indicated in this manual. These instructions are not inten-
ded to cover as many as possible conditions and situations which may arise. As with all hou-
sehold appliances installation, operation and conservation should  be carried out prudently
and following common sense.

In the case that the power cable becomes damaged, this must be substituted only by spe-
cialised personnel authorised by the manufacturer.

Do not cover this appliance with bags when is not in use.

Unventilated area where the appilance using flammable refrigerants is installed shall be  so
constructed that any leaked refrigerants will not stagnate so as to cause a fire or an explosion
hazard caussed by igniting stagnant refrigerants from other source such as electric heater,
stove and similar home applications.

This appliance contains substances which, if released into the atmosphere, would damage the
ozone layer. Care should therefore be taken not to perforate the refrigerant circuit. At the end of
its working life, deliver the air conditioning unit to a special collection centre.

GB  19-06-2003  9:09  Pagina 4

Summary of Contents for Pinguino FX160ECO

Page 1: ...ar the unit The unit should be transported in a vertical position If this is not possible secure the unit at an angle do not lie horizontally Before transporting the unit drain the condensation collec...

Page 2: ...even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas losing excess heat and moisture before being discharged again into the room In...

Page 3: ...r intake grill 8 Rating plate 9 Water collection tank 10 Water drain tube 11 Stopper for drain tube 12 Power cord Description of the Accessories 13 Stopper and flange 14 Air exhaust hose 15 Air exhaus...

Page 4: ...e 14 Place the air conditioning unit at a win dow or French window Open the window a little and position the attachment 15 as shown in fig 2 1 Setting up 2 3 Pinguino is equipped with an adjustable wi...

Page 5: ...closed off with the flange stop per 12 N B When operating the appliance with semi per manent installation it is advisable to leave a door slightly ajar even only 1cm 0 4 to ensure free circulation of...

Page 6: ...a ges due to failure in following normal safety procedures Replacement of the power cable must be carried out by qualified personnel THE DISPLAY A ON OFF Button B Function Button Air conditioning dehu...

Page 7: ...eed by pressing the FAN button Q until the fan speed indicator appears MAX P if you want the maximum power of the air conditioner to reach the desired temperature as quickly as possi ble MIN O if you...

Page 8: ...t function Connect the appliance to the mains supply and press ON OFF button next select the required operating mode temperature fan speed etc Press the ON OFF button again the appliance will go into...

Page 9: ...re FULL TANK Empty the tank at the rear of the appliance and reposition correc tly THIS UNIT EMPLOYS AN EXCLUSIVE CON DENSATION RECYCLING SYSTEM TO DISPO SE OF EXCESS MOISTURE IN NORMAL CONDITIONS CON...

Page 10: ...xchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest objects on the air cond...

Page 11: ...8 To remove the dust deposited on the anti bacterial filter use a vacuum cleaner If very dirty immerse in warm water not more than 40 C and rinse thoroughly Allow the filter to dry To replace fit the...

Page 12: ...is set too high air filters are dirty the capacity of the air conditioner is not adequate for the conditions or the dimen sions of the room close the window eliminate source of heat set the thermostat...

Page 13: ...p fuse If the plug is a moulded on type the fuse cover must be re fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be...

Page 14: ...010500 06 03 D e L o n g h i S p A V i a L S e i t z 4 7 3 1 1 0 0 Tr e v i s o I t a l i a t e l 3 9 0 4 2 2 4 1 3 1 f a x 3 9 0 4 2 2 4 1 3 6 4 7 w w w d e l o n g h i c o m GB 19 06 2003 9 09 Pagin...

Reviews: