background image

24

The following instructions will help you set up your air conditioning unit as efficiently as possible. 

AIR CONDITIONING WITHOUT INSTALLATION
FOR INSTANT TEMPORARY USAGE

With just a few simple operations, Pinguino will
restore comfortable conditions in your room:

Fix the exhaust hose 

to the coupling

on the back of the unit as shown in figu-

re 

A

.

12

16

With a double casement window, use the
suckers

provided to hold the two hal-

ves of the window together (fig. 

C

).

18

Fix the window attachment 

to the end

of the hose 

.

Place the unit near a window French win-
dow or door.

Open the window, French window or door
slightly and place the window attachment

as shown in figure

B

.

17

17

16

De s c r i p t i o n   a n d   s e t t i n g   u p

1

2

A

B

C

DESCRIPTION OF THE APPLIANCE

1) Remote control unit compartment with

cover

2) Control panel

3) Manual function button

4) Air outlet grill

5) Open-out handle

6) Front panel

7) Tray 

8) Tank

9) Reset button

10) Air intake grill

11) Handle

12) Air exhaust hose fitting

13) Drain tube

14) Air intake grill

15) Flange bung

16)Air exhaust hose

17) Nozzle for air exhaust hose

18) Suction cups

19) Wheel locks

20) Descaling liquid

Summary of Contents for PINGUINO 70ECO

Page 1: ...rant gases that may leak from the appliance do not remain in the room thereby causing a fire hazard This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres o...

Page 2: ...ing excess heat and moisture before being discharged again into the room In single unit models Pinguino a small part of this air is used to cool the refrigerant gas befo re hot and moist air is being...

Page 3: ...C 18 Fix the window attachment to the end of the hose Place the unit near a window French win dow or door Open the window French window or door slightly and place the window attachment as shown in fi...

Page 4: ...ough the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 106 MAX 120 cm MIN 30 cm When the hose is not attached close the hole with the bung on the flange NOTE When the...

Page 5: ...e water will also be used more quickly You may also use the airconditioner on air cooling only without filling the water tank If you only requi re the lower cooling power 16 8 A To open the front pane...

Page 6: ...f the remote control When the remote control is not used it can be stored in the foreseen compartment To open the compartment press push 1 SLEEP TIM ER MODE SW I NG FAN SMART SUPE R Low Low High High...

Page 7: ...or maximum comfort F SUPER button Starts or stops rapid cooling in the rapid cooling mode the fan operates at high speed with the temperature automatical ly set at 18 C G SLEEP button Sets or cancels...

Page 8: ...ir conditioning dehumidifier fan or heater TIMER if the TIMER mode is selected the indicator lights remain on even when the appliance is off FORCED OPERATIONS This is a way of operating to be selected...

Page 9: ...hazard When the remote control unit batteries are replaced the air conditioning indicator and heating indicator will flash alterna tely on the remote control unit liquid crystal display To set the re...

Page 10: ...on A beep indicates that the air conditioning unit is on and the symbol flashes on the display Press the MODE button a number of times until the dehumidifying symbol appears on the display Use the but...

Page 11: ...ning dehumidifying fan or SMART to be gradually reduced until it shuts down completely after eight hours To select SLEEP mode proceed as follows Press the button to turn the appliance on A beep indica...

Page 12: ...l flashes Set the time when you want the appliance to go off using the buttons from 30 minutes to 24 hours Press the TIMER button again to confirm the selection A count down of the time left is displa...

Page 13: ...ore A If you wish to use the purification filter Remove the purification filter from the filter housing Remove the aspiration grill fig F on page 36 and the dust filter which is atta ched to this Remo...

Page 14: ...window to guarantee an adequate exchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do...

Page 15: ...er draining off the water replace the drainage hose plug remove the dirt by scrubbing gently with a cloth where the tank is positioned START OF SEASON CHECKS Check that the power cable and socket are...

Page 16: ...hour air conditioning function 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open and the a...

Page 17: ...The unit works but does not cool the room a window is open in the room there is some source of heat lamp burner etc or there are many peo ple in the room the thermostat is set too high the air filter...

Page 18: ...e fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fuse cover can be obtained from your ne...