background image

PREPARING THE UNIT FOR USE

1) Fit the exhaust tube in place; if your conditioner is supplied with

but is best used at minimum length. 

Never stretch the hose.

HOW TO PREPARE WATER CONTAINER

Use only clean, salt-free tap water. The water is essential for the air cooling operation and is discharged
in the form of steam through the exhaust outlet. A container full of water lasts for a period that depends
on a number of conditions such as temperature, humidity, insulation, exposure of the room, number of
people present, etc. On average it will last approximately 7 to 10 hours.
When the container is empty, the appliance automatically changes function from water to air. At the same
time, the quantity of air discharged from the rear hose will increase.

Open the water container compartment
door, tip the container forwards and lift
up to remove.

After filling, replace the extendable tube,
screw the cap on tightly and return the
container to its place, making sure the
word FRONT is facing out.

Remove the cap, pull out the extendable
tube and fill the container, standing it on
the floor.

During “water condensation” cooling function and in particularly quiet surroundings (eg. bedroom), a
slight gurgling noise may be heard. This may be regarded as perfectly normal.

Attention: Do not use water containing cooking salt or decalcified water which has been decalcified
through the use of certain salts.

a bayonet tube, it is fitted as illustrated in the
diagram.

2) For  permanent installation, place the appli-

ance near the wall or window outlet. Make
sure it is standing on a level surface and fit the
special shock absorbers/castor stops under-
neath the castors.

3) The exhaust hose can be compressed or

extended between 500 mm. and 1400 mm.,

1

2

Summary of Contents for PACCT 250

Page 1: ...ime and effort to read this manual carefully Becoming familiar with the Pinguino is an essential step if you are to benefit fully from its exceptional qualities during both installation and actual use...

Page 2: ...nditioning function TECHNICAL DATA Tab 1 IDEAL OPERATING CONDITIONS Tab 2 ROOM TEMPERATURE 21 32 C ROOM HUMIDITY FACTOR BELOW 80 WATER FUNCTION AIR FUNCTION Power supply voltage V 220 240 V Frequency...

Page 3: ...llecting tray Water container compartment door Air filter Air intake grid Warranty envelope Exhaust hose compartment Handle Water collecting tray drainage tube Power cable compartment Castors Castor s...

Page 4: ...PARTS SUPPLIED DESCRIPTION Exhaust hose Stopper flange Castor stop De scaling fluid Window nozzle Suction cup set 1 1 2 1 1 1...

Page 5: ...rench window this temporary installation can be used at any time until it is ready for permanent installation Note In either case check that the unit is resting on at perfectly level surface If necess...

Page 6: ...FOR HEATING FUNCTION Model CT250H The unit is simply placed in the room to be heated there is no need for the discharge hose to be installed ELECTRICAL CONNECTIONS The mains supply suitable for domes...

Page 7: ...r container compartment door tip the container forwards and lift up to remove Afterfilling replacetheextendabletube screw the cap on tightly and return the container to its place making sure the word...

Page 8: ...stallation in which case a window must be left partially open the room is well shaded from direct sunlight by drawing curtains and or partially lowering blinds or shutters to avoid excessive energy co...

Page 9: ...switch in the TIMER ON position the TIMER ON OFF warning light on the control panel will light up 2 Set the operating times by pushing out the notches on the dial corresponding to the period required...

Page 10: ...light will turn on Select the programmed or non programmed mode see previous page The button C must be released Turn the thermostat toward theMax Coldposition thick green line The appliance will turn...

Page 11: ...indicates the correct time see instructions on setting 4 Select the desired function as shown in the chart overleaf The unit will now switch on and off each day at the selected times Note To override...

Page 12: ...non programmed mode see previous page Select the fan speed required pressing Fan speed key C AIR CONDITIONING TurnthethermostattoMax Cold Press key A ON OFF The ON OFF signal lamp will come on The ap...

Page 13: ...plug from the electrical outlet Do not use the power supply cable to pull the appliance when moving it Do not install the appliance in rooms where the air might contain traces of gas oil or sulphur o...

Page 14: ...onth to prevent dirt from accumulating after prolonged use 1 Switch off the appliance and disconnect the plug 2 Open the water container compartment door and remove the container 3 Remove the plug fro...

Page 15: ...nt sufficiently window open source of heat in room heater lamp etc room is overcrowded with people air exhaust hose has become disconnected thermostat regulated too high air filter blocked close windo...

Page 16: ...t c Leave the air conditioner to operate for about half an hour d Drain away all the fluid left in the tray and rinse thoroughly The drainage tube should be open and the appliance switched on during d...