23
FEEDER CABLE SECTION
Type “H05RR-F”
3 x 1,5 mm
2
POWER SUPPLY
230 V 50 Hz 3210 W
CONNECTION OF THE POWER SUPPLY CABLE
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
•
Unhook the terminal board cover by inserting a screwdriver into the two hooks “
A
” (fig. 3.1).
•
Unscrew the screw “
D
” and open completely the cable clamp “
E
” (fig. 3.2).
•
Connect the phase, neutral and earth wires to terminal board “
G
” according to the
diagram in fig. 3.3.
•
Strain the feeder cable and block it with cable clamp “
E
” (by screwing screw “
D
”).
•
Close the terminal block cover (check the two hooks “
A
” are correctly hooked).
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
NOTE: The earth conductor must be left about 3 cm longer than the others.
1
2
3
5
4
N
L2
PE
L1
G
D
E
PE
N
L
Fig. 3.3
Fig. 3.2
Fig. 3.1
220-240 V ac
A