INSTALLATION
CAUTION:
■
This appliance must be installed in accordance with these installation
instructions.
■
This appliance shall only be serviced by authorized personnel.
■
This appliance is to be installed only by an authorised person.
■
Incorrect installation, for which the manufacturer accepts no responsibility,
may cause personal injury of damage.
■
Always disconnect the cooker from mains power supply before carrying out
any maintenance operations or repairs.
■
In the room where the cooker is installed, there must be enough air to
allow the gas to burn correctly, according to the current local regulations.
ELECTRICAL REQUIREMENTS
■
The appliance must be connected to the mains checking that the voltage corre-
sponds to the value given in the rating plate and that the electrical cable sec-
tions can withstand the load specified on the plate.
■
The plug must be connected to an earthed socket in compliance with safety
standards.
■
If the appliance is supplied without plug, fit a standard plug which is suitable for
the power consumed by the appliance.
■
The appliance must be connected directly to the mains placing a two pole
switch with minimum opening between the contacts of 3 mm between the
appliance and the mains.
■
The power supply cable must not touch the hot parts and must be positioned so
that it does not exceed 50°C above ambient.
■
Once the appliance has been installed, the switch or socket must always be
accessible.
■
If the supply cord is damaged it must be replaced by the manufacturer or
it’s Service Agent or a similarly qualified person in order to avoid a hazard.
WARNING: This cooker must be connected to electrical supply using
V105 insulated cable.
N.B. The connection of the appliance to earth is mandatory.
If the installation requires alterations to the domestic electrical system call a qualified
electrician.
He should also check that the socket cable section is suitable for the power drawn by
the appliance.
Appliance power rating:
230 V~ 3345 W (14.5 A)
240 V~ 3640 W (15.1 A)
Replacing the power cord must be done by a qualified electrician in accor-
dance with the instructions supplied by the manufacturer and in compliance