I N S T A L L A T I O N
Figure 1.3
Figure 1.4
CLEARANCES
■
Installation clearances and protection of combustible surfaces shall
comply with the current local regulations eg. AG 601 (AS 5601) Gas
Installations code.
■
Installation shall comply with the dimension in Fig 1.4 bearing in mind
that
Overhead Clearances
■
In no case shall the clearances between the highest part of the cooker
be less than 600mm or for an overhead exhaust fan 750mm. All other
downward facing combustible surfaces less than 600mm above the
cooker surface shall be protected for the full width of the cooking surface
in accordance with the standards noted above. In no case shall the
clearance be less than 450mm.
Rear and Side Clearances
■
Where the dimensions from the periphery of the nearest burner to any
vertical combustible surface is less than 200mm the surface shall be
protected in accordance with the standards to a height of not less than
150mm above the cooking surface for the full width or depth of the
cooking surface
■
Where the dimensions from the periphery of the nearest burner to any
horizontal combustible surface is less than 200mm, the horizontal surface
shall be greater than 10mm below the surface of the hob, or the
horizontal surface requirement above.
Protection of combustible surfaces.
■
The standards above specify that where required protection shall ensure
that the surface temperature of the combustible surface does not exceed
65°C above room temperature.
If the cooker is located on a pedestal it is necessary to provide safety measures
to prevent falling out.
203 mm
608 mm
1216 m
m
min 915 mm
max 927 mm