12
CONVERSION PROCEDURE (to convert to Universal LPG)
REPLACING THE INJECTORS
The conversion procedure must be carried out only by an authorised person.
This appliance is suitable for use with Natural gas or Universal LPG (check the “gas
type” sticker attached to the appliance). A label stating the type of gas used after
replacing the injectors must be attached at the rear of the appliance, in proximity of the
gas inlet connection. The nominal gas consumption and injector size details are pro-
vided in table at page 15.
To replace the injectors proceed as follows:
■
Remove pan supports and burners from the cooktop.
■
Using a spanner, remove the injectors J (figs. 1.17a, 1.17b, 1.17c) and replace
them with the correct ones according to the gas type (see following tables -
page 15).
■
Affix to the rear of the appliance, in proximity of the gas inlet connections, the
warning label (supplied with the conversion kit) stating that the cooker has been
converted for use with Universal LPG / Natural gas.
IMPORTANT
■
If the cooker is suitable for use with Natural gas and must be converted for use
with Universal LPG, before connecting to gas main remove the appliance gas
regulator and replace with test point adaptor (see figs. 1.14a-1.14b).
■
If the cooker is suitable for use with Universal LPG and must be converted for
use with Natural gas, before connecting to the gas main remove the appliance
test point adaptor and replace with gas regulator (see figs. 1.14a-1.14b).
NOTE:
Gas regulator and test point adaptor are supplied with the appliance (packed with con-
version kit).
The burners are designed so that regulation of primary air is not required.
Rapid
burner
Triple ring
burner
DUAL
burner
J
Injector for inner crown
J
Injectors for
outer crowns
J
J
I N S T A L L A T I O N
Figure 1.17c
Figure 1.17b
Figure 1.17a
Summary of Contents for AP 1246 G
Page 56: ...Rif 1688 5...