OPERATING INSTRUCTIONS 

-User Guide- 

 
 

NAVIGATION: 

The meter uses an on-screen, menu-driven approach to navigate through the meter features, 

allowing for an intuitive understanding of keypad functions. Each screen presents the user with a 

number of selectable options. One of the options is always selected and the user can move 

(navigate) the selection to any other available option. The keypad is aimed at providing 

navigational control, and not at accessing specific features. There are four directional keys 

aligned intuitively around a middle (fifth) key (see Figure 1): Above (UP), below (DOWN), to the 

right (RIGHT) and to the left (LEFT). The middle key is used to SELECT the option highlighted on 

the screen. For purposes of this owner’s manual, the five keys will be referred to as 

ï ð ñ ò 

and SELECT.  

 

INSTALLING THE BATTERY: 

The battery compartment is located on the underside of the case, at the bottom of the handle.   
 

1.  Open the battery compartment by sliding the lid back while  pressing on the release indent. 

2.  Ensure correct polarity, and push the  battery in flush with the bottom board until the 

connectors snap together on both sides. 

3.  Replace the battery compartment lid. 

 

LOW BATTERY:  

The meter features a battery status monitor designed to warn the user as well as protect 

measurement accuracy from impending battery failure conditions. The battery warning is 

triggered by either continuous or temporary low voltage conditions. Visible (a battery icon on the 

top right side of the display) and audible (buzzer warble) indicators will appear when these low 

voltage conditions occur.  

Once a permanent low battery condition is detected, all measurement functions are disabled. The 

battery should be replaced immediately. If the battery reaches critically low levels, the meter will 

refuse to stay on at power-up.  This gradual warning system is intended to provide the user 

advanced battery status notice and give ample time for replacement before operational limitations 

occur.  

NOTE:

  Current meter settings are not lost during battery replacement or low battery conditions. 

 

 

Summary of Contents for QuickNav

Page 1: ...QuickNav MOISTURE METER Owner s Manual Version 1 0 Delmhorst Instrument Co Rev 1 June 2011...

Page 2: ...READINGS 5 6 TO TAKE DRYWALL READINGS 6 TO TAKE SCAN READINGS 7 TO TAKE TEMP RH READINGS 7 TO SET THE ALARM IN WOOD DRYWALL SCAN MODE 8 MAIN MENU OPTIONS 8 TAKING A READING PRACTICAL APPLICATIONS 9 TE...

Page 3: ...the range of 0 100 with accuracy of 2 over 10 90 Measures temperature over the range of 40 F 255 F with accuracy of 1 8 F over 4 F to 158F range of 40 C 124 C with accuracy of 1 C over 20 to 70 C Calc...

Page 4: ...Open the battery compartment by sliding the lid back while pressing on the release indent 2 Ensure correct polarity and push the battery in flush with the bottom board until the connectors snap togeth...

Page 5: ...ice The next screen is the MAIN MENU Use the keys to select the desired function mode and then press SELECT to activate the function Keypad Layout METER USE TO TAKEWOOD READINGS 1 From the Main Menu u...

Page 6: ...the key to highlight DRYWALL Then use the SELECT key to enter the pin mode 2 The meter will display the DRYWALL screen as shown below 3 Push the contact pins into the drywall Any Delmhorst electrode m...

Page 7: ...T mode firmly insert the RH T S1 sensor into the top of the meter making sure to align the pin out on the DIN connector 1 From the Main Menu use the key to highlight RH T Then press the SELECT key to...

Page 8: ...RYWALL or SCAN mode screen and an audible alarm will sound if that value is reached Note Default alarm settings are WOOD 15 DRYWALL 1 SCAN 300 MAIN MENU OPTIONS METRIC IMPERIAL This option will toggle...

Page 9: ...ipes or condensation on cold water lines in attic or hollow walls Faulty flashing around windows doors and where porch and dormer roofs meet sidings End grain wood that is not sealed with paint at all...

Page 10: ...o the hole and sealed to the concrete 4 Insert the protective yellow cap into the sleeve and let the hole acclimate for 72h 5 Remove the cap and immediately insert the sensor to full hole depth Wait a...

Page 11: ...ction and climatic conditions Subsurface test Drill two 1 4 holes 3 4 apart and 1 2 to 2 deep Drive the masonry nails into the bottom of the holes and make the tests as described above Nails must not...

Page 12: ...eter scale The meter displays the MC for two seconds USING SCAN MODE You can also take a reference reading on drywall using the meter s SCAN mode To take a reading firmly press the back of the meter o...

Page 13: ...tion of the pinless mode may be adversely affected Under these conditions allow the meter to acclimate to the temperature conditions in which it will be used for minimum of 1 2 hours or as long as pos...

Page 14: ...is not working properly replace the battery with a new one and check the calibration If this does not resolve the problem go to www delmhorst com and follow the instructions under the Product Support...

Page 15: ...ld stay in calibration follow the instructions in the Care of Your Meter section UNDER NO CIRCUMSTANCES SHALL DELMHORST BE LIABLE FOR ANY INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY TY...

Page 16: ...20 5 22 GUM RED 7 8 9 10 12 5 14 5 16 5 19 20 5 22 5 24 HEMLOCK WESTERN 7 8 9 10 5 13 15 17 19 20 5 22 23 5 HACKBERRY 7 8 5 9 9 5 12 13 15 17 18 5 20 22 HICKORY 8 8 5 9 10 11 12 5 14 15 5 17 19 20 5...

Page 17: ...4 5 17 19 21 23 5 26 SPF 9 10 11 5 13 15 5 18 20 5 23 25 28 30 SPF COFI 8 9 10 11 13 15 17 19 21 23 25 TEAK 7 8 8 5 9 11 12 14 15 17 18 5 20 VIROLA 6 5 7 8 9 11 12 5 14 16 18 18 5 20 5 WALNUT BLACK 7...

Reviews: