WARRANTY 

 

Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees the QuickNav  meter for 
one year from date of purchase and any optional electrodes against defects in material or 
workmanship for 90 days. If, within the warranty period of the Model QuickNav, you find any 
defect in material or workmanship, return the meter following the instructions in the “

Service for 

Your Meter”

 section.

 

This warranty does not cover abuse, alteration, misuse, damage during 

shipment, improper service, unauthorized or unreasonable use of the meter or electrodes. This 
warranty does not cover batteries, pin assemblies, or pins.

 

If the meter or any optional electrodes 

have been tampered with, the warranty shall be void.  At our option, we may replace or repair the 
meter. 

 

Delmhorst shall not be liable for incidental or consequential damages for the breach of any 
express or implied warranty with respect to this product or its calibration. With proper care and 
maintenance the meter should stay in calibration; follow  the instructions in the “

Care of Your 

Meter”

 section.  

 
UNDER NO CIRCUMSTANCES SHALL DELMHORST BE LIABLE FOR ANY INCIDENTAL, 
INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES OF ANY TYPE WHATSOEVER, 
INCLUDING, BUT NOT LIMITED TO, LOST PROFITS OR DOWNTIME ARISING  OUT OF OR 
RELATED IN ANY RESPECT TO ITS METERS OR ELECTRODES AND NO OTHER 
WARRANTY, WRITTEN, ORAL OR IMPLIED APPLIES. DELMHORST SHALL IN NO EVENT BE 
LIABLE FOR ANY BREACH OF WARRANTY OR DEFECT IN THIS PRODUCT THAT 
EXCEEDS THE AMOUNT OF PURCHASE OF THIS PRODUCT. 
 
The express warranty set forth above constitutes the entire warranty with respect to Delmhorst 
meters and electrodes and no other warranty, written, oral, or implied applies. This warranty is 
personal to the customer purchasing the product and is not transferable.   

 

 

 

Delmhorst Instrument Co. 

51 Indian Lane East 

Towaco NJ 07082 

 877-DELMHORST   

www.delmhorst.com 

E-mail - 

[email protected] 

 

For 65 years Delmhorst Instrument has been  the leading manufacturer of high quality, US-made 
moisture meters and thermo-hygrometers. Today we offer a wide range of meters for applications 
including water damage restoration, construction, flooring, lumber/woodworking, paper, and 
agriculture.

 

 
 
 
 
 
 
 
 
 
 
 

510INS-0031 

 

REV 06/2011 

 

Summary of Contents for QuickNav

Page 1: ...QuickNav MOISTURE METER Owner s Manual Version 1 0 Delmhorst Instrument Co Rev 1 June 2011...

Page 2: ...READINGS 5 6 TO TAKE DRYWALL READINGS 6 TO TAKE SCAN READINGS 7 TO TAKE TEMP RH READINGS 7 TO SET THE ALARM IN WOOD DRYWALL SCAN MODE 8 MAIN MENU OPTIONS 8 TAKING A READING PRACTICAL APPLICATIONS 9 TE...

Page 3: ...the range of 0 100 with accuracy of 2 over 10 90 Measures temperature over the range of 40 F 255 F with accuracy of 1 8 F over 4 F to 158F range of 40 C 124 C with accuracy of 1 C over 20 to 70 C Calc...

Page 4: ...Open the battery compartment by sliding the lid back while pressing on the release indent 2 Ensure correct polarity and push the battery in flush with the bottom board until the connectors snap togeth...

Page 5: ...ice The next screen is the MAIN MENU Use the keys to select the desired function mode and then press SELECT to activate the function Keypad Layout METER USE TO TAKEWOOD READINGS 1 From the Main Menu u...

Page 6: ...the key to highlight DRYWALL Then use the SELECT key to enter the pin mode 2 The meter will display the DRYWALL screen as shown below 3 Push the contact pins into the drywall Any Delmhorst electrode m...

Page 7: ...T mode firmly insert the RH T S1 sensor into the top of the meter making sure to align the pin out on the DIN connector 1 From the Main Menu use the key to highlight RH T Then press the SELECT key to...

Page 8: ...RYWALL or SCAN mode screen and an audible alarm will sound if that value is reached Note Default alarm settings are WOOD 15 DRYWALL 1 SCAN 300 MAIN MENU OPTIONS METRIC IMPERIAL This option will toggle...

Page 9: ...ipes or condensation on cold water lines in attic or hollow walls Faulty flashing around windows doors and where porch and dormer roofs meet sidings End grain wood that is not sealed with paint at all...

Page 10: ...o the hole and sealed to the concrete 4 Insert the protective yellow cap into the sleeve and let the hole acclimate for 72h 5 Remove the cap and immediately insert the sensor to full hole depth Wait a...

Page 11: ...ction and climatic conditions Subsurface test Drill two 1 4 holes 3 4 apart and 1 2 to 2 deep Drive the masonry nails into the bottom of the holes and make the tests as described above Nails must not...

Page 12: ...eter scale The meter displays the MC for two seconds USING SCAN MODE You can also take a reference reading on drywall using the meter s SCAN mode To take a reading firmly press the back of the meter o...

Page 13: ...tion of the pinless mode may be adversely affected Under these conditions allow the meter to acclimate to the temperature conditions in which it will be used for minimum of 1 2 hours or as long as pos...

Page 14: ...is not working properly replace the battery with a new one and check the calibration If this does not resolve the problem go to www delmhorst com and follow the instructions under the Product Support...

Page 15: ...ld stay in calibration follow the instructions in the Care of Your Meter section UNDER NO CIRCUMSTANCES SHALL DELMHORST BE LIABLE FOR ANY INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY TY...

Page 16: ...20 5 22 GUM RED 7 8 9 10 12 5 14 5 16 5 19 20 5 22 5 24 HEMLOCK WESTERN 7 8 9 10 5 13 15 17 19 20 5 22 23 5 HACKBERRY 7 8 5 9 9 5 12 13 15 17 18 5 20 22 HICKORY 8 8 5 9 10 11 12 5 14 15 5 17 19 20 5...

Page 17: ...4 5 17 19 21 23 5 26 SPF 9 10 11 5 13 15 5 18 20 5 23 25 28 30 SPF COFI 8 9 10 11 13 15 17 19 21 23 25 TEAK 7 8 8 5 9 11 12 14 15 17 18 5 20 VIROLA 6 5 7 8 9 11 12 5 14 16 18 18 5 20 5 WALNUT BLACK 7...

Reviews: