29I DELLMECO I EODD DIAPHRAGM PUMPS
6.3. Connecting the ground wire
a) When installing the conductive pump, be sure to connect the ground wire at the specified position.
b) Ground wires should be connected to peripheral equipment and piping as well.
c) Use 2.0 mm
2
minimum ground wire.
6.4. Electric connections
Install electric connections between the three-phrase motor, frequency converter and control devices according to
the terminal plan supplied.
6.5. Before you start the pump
1) Connect a hose to the valve on the suction-port side and to the discharge-port side of the pump.
2) Connect a hose on the suction-side intake and the discharge-port side to the respective vessels.
3) Check oil level in the crankshaft mechanism via the transparent plug (plug location on the picture below).
Required amount of oil for different sizes of DME Series Pumps in the below chart:
Oil level in the crankshaft mechanism cannot exceed the red dot located in the centre of the transparent oil indicator plug!
Pump model
Crankshaft
oil type
Estimated
oil amount,
[ml]
DME 15 Plastic, DME 20 Metal, DME 25 Hygienic
GM Dexos2
5W-30
100
DME 25 Plastic, DME 25 Metal, DME 40 Hygienic
150
DME 40 Plastic, DME 40 Metal, DME 50 Hygienic
450
DME 50 Plastic, DME 50 Metal, DME 65 Hygienic
500
DME 80 Plastic, DME 80 Metal, DME 80 Hygienic
1100
!
WARNING
!
WARNING
Ground wires must be connected to the piping and any other peripheral equipment. When operating the
pump make sure it is properly grounded. Otherwise friction between the parts and abrasion caused by
some fluids flowing inside the casing may generate static electricity. In addition it may cause fire or electric
shock, depending on the type of fluid being pumped and the installation environment (such as gases in the
air or the surrounding mixtures).
Only appropriately educated professional personnel may carry out with any electric works!
Keep the terminal plan in the distribution cabinet!
Summary of Contents for DME 15 R Series
Page 15: ...15I DELLMECO I EODD DIAPHRAGM PUMPS 5 4 DME 50 A C S Metal Series Diaphragm Pump exploded view...
Page 16: ...16 I DELLMECO I EODD DIAPHRAGM PUMPS 5 5 DME 80 A B Metal Series Diaphragm Pump exploded view...
Page 17: ...17I DELLMECO I EODD DIAPHRAGM PUMPS 5 6 DME 80 S Metal Series Diaphragm Pump exploded view...
Page 21: ...21I DELLMECO I EODD DIAPHRAGM PUMPS 5 8 DME 65 H Hygienic Series Diaphragm Pump exploded view...
Page 22: ...22 I DELLMECO I EODD DIAPHRAGM PUMPS 5 9 DME 80 H Hygienic Series Diaphragm Pump exploded view...
Page 39: ...39I DELLMECO I EODD DIAPHRAGM PUMPS DME Plastic Series Flow Characteristics...
Page 43: ...43I DELLMECO I EODD DIAPHRAGM PUMPS DME Metal Series Flow Characteristics...
Page 45: ...45I DELLMECO I EODD DIAPHRAGM PUMPS DME Hygienic Series Flow Characteristics...
Page 65: ...Notes...