![Dell PowerEdge R420xr Owner'S Manual Download Page 118](http://html.mh-extra.com/html/dell/poweredge-r420xr/poweredge-r420xr_owners-manual_85444118.webp)
Error Code
Message Information
MEM8000
Message
Correctable memory error logging disabled for a memory
device at location <
location
>.
LCD Message
SBE log disabled on <
location
>. Re-seat memory.
Details
Errors are being corrected but no longer logged.
Action
Review system logs for memory exceptions. Reinstall
memory at location <
location
>.
PCI1302
Message
A bus time-out was detected on a component at bus <
bus
>
device<
device
> function <
func
>.
Details
System performance may be degraded. The device has failed
to respond to a transaction.
Action
Cycle input power, update component drivers, if device is
removable, reinstall the device.
PCI1304
Message
An I/O channel check error was detected.
LCD Message
I/O channel check error detected. Power cycle system.
Action
Cycle input power, update component drivers, if device is
removable, reinstall the device.
PCI1308
Message
A PCI parity error was detected on a component at bus
<
bus
>device<
device
>function <
func
>.
LCD Message
PCI parity error on bus <
bus
> device <
device
> function
<
func
>. Power cycle system.
Details
System performance may be degraded, PCI device may fail
to operate, or system may fail to operate.
Action
Cycle input power, update component drivers, if device is
removable, reinstall the device.
PCI1320
Message
A bus fatal error was detected on a component at bus
<
bus
>device<
device
>function <
func
>.
LCD Message
Bus fatal error on bus <
bus
> device <
device
> function
<
func
>. Power cycle system.
Details
System performance may be degraded, or system may fail to
operate.
Action
Cycle input power, update component drivers, if device is
removable, reinstall the device.
118