![Dell PowerEdge R420xr Owner'S Manual Download Page 117](http://html.mh-extra.com/html/dell/poweredge-r420xr/poweredge-r420xr_owners-manual_85444117.webp)
Error Code
Message Information
MEM0007
Message
Unsupported memory configuration; check memory device
at location <
location
>.
LCD Message
Unsupported memory configuration. Check memory
<
location
>.
Details
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
Getting Help
.
MEM0701
Message
Correctable memory error rate exceeded for <
location
>.
Details
The memory may not be operational. This an early indicator
of a possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
MEM0702
Message
Correctable memory error rate exceeded for <
location
>.
LCD Message
Correctable memory error rate exceeded for <
location
>. Re-
seat memory.
Details
The memory may not be operational. This an early indicator
of a possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
MEM1205
Message
Memory mirror redundancy is lost. Check memory device at
location(s) <
location
>.
LCD Message
Memory mirror lost on <
location
>. Power cycle system.
Details
The memory may not be seated correctly, misconfigured, or
has failed.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
Getting Help
.
MEM1208
Message
Memory spare redundancy is lost. Check memory device at
location <
location
>.
LCD Message
Memory spare lost on <
location
>. Power cycle system.
Details
Memory sparing is no longer available.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
117