Information Update
17
E171F
PCIE Fatal Err
B## D## F##
The system BIOS has
reported a PCIe fatal error
on a component that
resides in PCIe
configuration space at bus
##, device ##, function
##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see “Troubleshooting
Expansion Cards” in
the
Hardware Owner’s
Manual.
PCIE Fatal Err
Slot #
The system BIOS has
reported a PCIe fatal error
on a component that
resides in the specified
slot.
Reinstall the expansion-
card riser. See “Expansion
Card Risers” in the
Hardware Owner’s
Manual.
If the problem persists,
the riser card or system
board is faulty. See
“Getting Help” in the
Hardware Owner’s
Manual.
E1914
DRAC5 Conn2
Cbl
DRAC 5 cable is missing
or disconnected.
Reconnect the cable. See
“Installing a RAC Card”
in the
Hardware Owner’s
Manual.
E1B01
USB#
Overcurrent
Device plugged in the
specified USB port caused
an overcurrent condition.
Reseat the device cable.
If the problem persists,
replace or remove the
device.
E2110
MBE DIMM # & #
One of the two indicated
DIMMs has had a memory
multi-bit error (MBE).
See “Troubleshooting
System Memory” in
the
Hardware Owner’s
Manual.
Table 1-2.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
Summary of Contents for PowerEdge 2900
Page 1: ...Dell PowerEdge 2900 Systems Information Update ...
Page 26: ...26 Information Update ...
Page 27: ...Dell PowerEdge 2900 系统 信息更新 ...
Page 49: ...信息更新 49 图 1 3 卸下系统板 1 固定插针 2 系统板 3 系统板手柄 2 4 机箱挂钩 1 2 3 4 ...
Page 50: ...50 信息更新 ...
Page 51: ...Systèmes Dell PowerEdge 2900 Mise à jour des informations ...
Page 79: ...Dell PowerEdge 2900 Systeme Aktuelle Informationen ...
Page 107: ...Dell PowerEdge 2900 システム アップデート情報 ...
Page 135: ...アップデート情報 135 図 1 3 システム基板の取り外し 1 保持ピン 2 システム基板 3 システム基板ハンドル 2 4 シャーシのフック 1 2 3 4 ...
Page 136: ...136 アップデート情報 ...
Page 137: ...Dell PowerEdge 2900 시스템 설명서 갱신본 ...
Page 162: ...162 설명서 갱신본 ...
Page 163: ...Sistemas Dell PowerEdge 2900 Actualización de información ...