14
Information Update
LCD Status Messages Update
Table 1-2 lists updates to the LCD status messages that can occur on
the PowerEdge 2900 III system and the probable cause for each message.
The LCD messages refer to events recorded in the system event log (SEL).
For information on the SEL and configuring system management settings,
see your systems management software documentation.
Warning: The
installed memory
configuration is
not optimal. For
more information
on valid memory
configurations,
please see
the system
documentation
on the technical
support web site.
Invalid memory
configuration. The system
runs but with reduced
functionality.
Ensure that the memory
modules are installed in
a valid configuration. See
“General Memory Module
Installation Guidelines”
in the
Hardware Owner’s
Manual
. If the problem
persists, see
“Troubleshooting System
Memory” in the
Hardware
Owner’s Manual
.
Write fault
Write fault on
selected drive
Faulty USB device, USB
medium, optical drive
assembly, hard drive, or
hard-drive subsystem.
Replace the faulty media.
Reseat the USB device or
USB cable. For hard drive
problems, see
“Troubleshooting a Hard
Drive” in the
Hardware
Owner’s Manual
.
Table 1-1.
System Messages
(continued)
Message
Causes
Corrective Actions
Summary of Contents for PowerEdge 2900
Page 1: ...Dell PowerEdge 2900 Systems Information Update ...
Page 26: ...26 Information Update ...
Page 27: ...Dell PowerEdge 2900 系统 信息更新 ...
Page 49: ...信息更新 49 图 1 3 卸下系统板 1 固定插针 2 系统板 3 系统板手柄 2 4 机箱挂钩 1 2 3 4 ...
Page 50: ...50 信息更新 ...
Page 51: ...Systèmes Dell PowerEdge 2900 Mise à jour des informations ...
Page 79: ...Dell PowerEdge 2900 Systeme Aktuelle Informationen ...
Page 107: ...Dell PowerEdge 2900 システム アップデート情報 ...
Page 135: ...アップデート情報 135 図 1 3 システム基板の取り外し 1 保持ピン 2 システム基板 3 システム基板ハンドル 2 4 シャーシのフック 1 2 3 4 ...
Page 136: ...136 アップデート情報 ...
Page 137: ...Dell PowerEdge 2900 시스템 설명서 갱신본 ...
Page 162: ...162 설명서 갱신본 ...
Page 163: ...Sistemas Dell PowerEdge 2900 Actualización de información ...