26
General System Configuration
NOTE:
A Gb Ethernet pass-through module is also available as an option and requires no configuration.
The Gb Ethernet pass-through module must be connected to a 1000 Mb port on the external switch
(10 Mb and 100 Mb ports are not supported).
Before configuring the switch, obtain the following information from your network administrator:
•
Username and password
•
The IP address to be assigned to the VLAN 1 interface through which the device is to be
managed
•
The IP subnet mask for the network
•
The IP address of the default gateway
To configure the PowerConnect 5316M Ethernet switch module using the internal serial port on
the DRAC/MC module, perform the following steps:
1
Log on to the DRAC/MC Telnet or serial interface.
2
To redirect the switch console through the DRAC/MC console, enter the following command:
connect
switch-
x
where
x
is the module slot number on the chassis. For example, if you are connecting to
switch module 1, type
connect
switch-1
3
Enter the following commands to enter and change to global configuration mode:
console>
enable
console#
configure
console(config)#
4
Set the user name and password with the highest privilege level of 15 with the following
command:
console(config)#
username
admin
password
secret
level
15
NOTE:
The username "admin" and password "secret" are used only for example—those fields are
user-selectable.
5
Configure the static address to be assigned to the VLAN interface as 192.168.1.123 (example
only) and subnet mask of 255.255.255.0 (example only) with the following commands:
console(config)#
interface
vlan
1
console(config-if)#
ip address
192.168.1.123 255.255.255.0
6
Configure the IP default gateway as 192.168.1.1(example only) with the following commands:
console(config-if)#
exit
console(config)#
ip default-gateway
192.168.1.1