6-24
Dell OptiPlex GXi Systems Service Manual
Figure 6-24. Microprocessor Removal
If the heat sink and microprocessor are separate, look at the bottom side of the
heat sink, and peel the thermal-pad protective cover off before attaching the
heat sink to the microprocessor.
To install the replacement microprocessor/heat sink assembly, ensure that the
microprocessor-socket release lever is in its fully vertical position to allow the
microprocessor pins to easily slip into the socket. When the microprocessor/
heat sink assembly is in place, rotate the microprocessor-socket release lever to
its horizontal position. Hook the microprocessor securing clip over the socket
tab nearest the right side of the system board, and then snap it over the tab on
the opposite side of the socket.
NOTE: Pin 1 on the microprocessor is located on the corner with the largest
bevel. The pin-1 hole in the microprocessor socket is located on the corner
where the holes are in a diagonal pattern.
heat sink
microprocessor securing clip
thermal interface pad
(attached to underside
of heat sink)
microprocessor
pin-1 corner of
socket
right tab
microprocessor-socket
release lever
front of computer
Summary of Contents for OptiPlex GXi
Page 1: ... HOO 2SWL3OH L 6 VWHPV 6 59 0 18 ...
Page 2: ......
Page 3: ... HOO 2SWL3OH L 6 VWHPV 6 59 0 18 ...
Page 16: ...xvi DELL CONFIDENTIAL Preliminary 6 16 97 ...
Page 18: ...xviii DELL CONFIDENTIAL Preliminary 6 16 97 ...
Page 64: ...3 10 Dell OptiPlex GXi Systems Service Manual ...
Page 142: ...A 6 Dell OptiPlex GXi Systems Service Manual ...
Page 146: ......
Page 147: ... www dell com Printed in the U S A P N 50560 Rev A01 ...