3-2
Dell PowerEdge 2100/180 and 2100/200 Systems Service Manual
1-3-1-3
Keyboard controller
error
Defective DIMMs or sys-
tem board. Reseat the
DIMMs or replace the sys-
tem board.
1-3-3-1
No DIMM memory
installed
Defective DIMMs or sys-
tem board. Reseat the
DIMMs or replace the sys-
tem board.
1-3-4-1
DRAM failure
Defective DIMMs or sys-
tem board. Reseat the
DIMMs or replace the sys-
tem board.
1-3-4-3
DRAM failure
Defective DIMMs or sys-
tem board. Reseat the
DIMMs or replace the sys-
tem board.
1-4-1-1
DRAM failure
Defective DIMMs or sys-
tem board. Reseat the
DIMMs or replace the sys-
tem board.
1-4-2-1
CMOS failure
Defective system board.
1-4-3-1
Memory controller or
DIMM failure
Defective DIMMs or sys-
tem board. Reseat the
DIMMs or replace the sys-
tem board.
2-1-2-3
Invalid ROM copy-
right notice
Defective system board.
2-2-3-1
Unexpected interrupt
Improperly seated expan-
sion card or the system
needs rebooted.
3-2-2-1
Gate A20 failure
Defective system board.
4-2-4-3
Keyboard controller
error
Defective DIMMs or sys-
tem board. Reseat the
DIMMs or replace the sys-
tem board.
4-2-4-4
Gate A20 failure
Defective system board.
Table 3-1. POST Beep Codes
(Continued)
Beep Code
Error
Probable Causes
Summary of Contents for Inspiron 2100
Page 2: ......
Page 3: ... Dell PowerEdge 2100 180 and 2100 200 Systems SERVICE MANUAL ...
Page 11: ...xiv DELL CONFIDENTIAL Preliminary 4 19 00 ...
Page 16: ...ix ...
Page 39: ...1 22 Dell PowerEdge 2100 180 and 2100 200 Systems Service Manual ...
Page 51: ...3 6 Dell PowerEdge 2100 180 and 2100 200 Systems Service Manual ...
Page 72: ......