Install the S60 System
|
20
The PWR Light Emitting Diode (LED) blinks until the boot-up sequence is complete. When the boot up
is complete, the PWD LED is steadily lit.
The Stack ID LED displays a digit to show the position of the unit in a stacking chain. For a single
chassis, a 0 displays.
AC Power
Connect the plug to each AC receptacle (
Figure 3-7
). Ensure the power cord is secure.
As soon as the cable is connected between the S60 system and the power source, the system is
powered-up; there is no on/off switch.
Figure 3-7.
AC Power Connection
DC Power
To connect DC power (
Figure 3-8
), follow these steps:
Figure 3-8.
DC power connection
Step
Task
1
Remove the small plastic cover from the DC connectors.
2
Attach the connectors to both the DC PSUs at the rear of the S60 system. Ensure the connection is secure.
3
Replace the plastic cover over the DC connectors.
4
Turn the power switch on.