Powering Up
|
35
9
Powering Up
Before you supply power to the chassis, Dell Force10 recommends that you re-inspect your equipment
rack and chassis. Verify that:
•
The equipment rack is properly secured and grounded.
•
The chassis is bolted and secured into your equipment rack.
•
Make sure the ambient temperature around the unit (which may be higher than the room temperature) is
within the limit specified for the unit.
•
Make sure there is sufficient airflow around the unit.
•
Make sure electrical circuits are not overloaded – consider the nameplate rating of all the connected
equipment, and make sure you have over current protection.
•
At least one power supply module is installed.
•
All power supply modules are properly installed.
•
All power supply modules are switched to the
OFF
(left) position.
•
The remote power source complies with the input power specifications in the section
System Power
Specifications on page 56
.
•
AC Power cables connect to the remote power source (if applicable).
•
The fan tray is installed and cannot be removed by pulling on the fan tray handle.
•
At least one RPM is installed.
•
All line cards and RPMs are properly installed and secured.
•
All chassis slots are filled. Blank panels and covers are installed in all empty slots.
•
Make sure no objects are placed on top of the unit.
To supply power to the C150 system:
WARNING:
Never operate the C150 System without a fan tray.
Step
Task
1
Verify that the power source complies with the system input power requirements in the section
System Power
Specifications on page 56
.
2
Energize the remote power source or outlet.
3
Toggle the switch on the AC power supplies to the
ON
(right) position.
Summary of Contents for Force10 C150
Page 1: ...Installing and Maintaining the C150 System ...
Page 6: ...6 Contents w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 16: ...16 Installing the C150 Chassis w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 34: ...34 Installing DC Power Entry Modules w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 38: ...38 Powering Up w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 55: ...System Specifications 55 Figure B 2 Chassis Dimensions Depth fnD0011mp 15 5 inches ...
Page 64: ...64 Contacting Technical Support w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 65: ......
Page 66: ...w w w d ell com support dell com Printed in the U S A ...