About Your System
19
E1414
CPU # Thermtrip
Specified microprocessor is out of
acceptable temperature range and
has halted operation.
See "Troubleshooting System
Cooling Problems" on page 105.
If the problem persists, ensure
that the microprocessor heat
sinks are properly installed. See
"Troubleshooting the
Microprocessors" on page 114.
NOTE:
The LCD continues to
display this message until the
system’s power cord is
disconnected and reconnected to
the AC power source, or the SEL is
cleared using either Server
Assistant or the BMC Management
Utility. See the
Dell OpenManage
Baseboard Management
Controller User’s Guide
for
information about these utilities.
E1418
CPU # Presence
Specified processor is missing or
bad, and the system is in an
unsupported configuration.
See "Troubleshooting the
Microprocessors" on page 114.
E1423
CPU # VRM
Missing
VRM for specified processor is
missing or faulty.
Remove and reseat the specified
VRM. See "Processor VRMs" on
page 66.
If the problem persists, the
system board is faulty. See
"Getting Help" on page 129.
E141C
CPU Mismatch
Processors are in a configuration
unsupported by Dell.
Ensure that your processors
match and conform to the type
described in the Microprocessor
Technical Specifications outlined
in your system’s
Getting Started
Guide
.
E141F
CPU Protocol
The system BIOS has reported a
processor protocol error.
See "Getting Help" on page 129.
E1420
CPU Bus PERR
The system BIOS has reported a
processor bus parity error.
See "Getting Help" on page 129.
E1421
CPU Init
The system BIOS has reported a
processor initialization error.
See "Getting Help" on page 129.
Table 1-7.
LCD Status Messages
(continued)
Line 1
Message
Line 2
Message
Causes
Corrective Actions
Summary of Contents for EMU01
Page 96: ...96 Installing System Components ...
Page 116: ...116 Troubleshooting Your System ...
Page 120: ...120 Running the System Diagnostics ...
Page 128: ...128 Jumpers and Connectors ...
Page 162: ...162 Glossary ...