You can install the pre-installation patch when the DataProtection-ACM is not
registered with Secure Remote Services gateway by using SSH.
Install the IDPA pre-installation patch on the DataProtection-ACM
Before you begin
Before you configure the DataProtection-ACM virtual machine, install the latest IDPA
pre-installation patch if it is available.
For example:
Idpa_pre_update_
N.N.N
.
nnnnnn
.tar.gz
Where:
l
N.N.N is the latest pre-installation patch version.
l
nnnnnn is the build number.
You can install the pre-installation patch when the DataProtection-ACM is not
registered with ESRS gateway by using SSH.
Procedure
1. Check
https://support.emc.com/downloads/41849_Integrated-Data-
to see if a pre-installation patch is available for your
version of IDPA. If a pre-installation patch is available, download it to a folder on
your laptop.
For example:
Idpa_pre_update_
N.N.N
.
nnnnnn
.tar.gz
Where:
l
N.N.N is the latest pre-installation patch version.
l
nnnnnn is the build number.
2. Open the WinSCP or SCP application on the service laptop, and then connect
to the DataProtection-ACM by performing the following actions:
a. In the File protocol field, select SFTP.
b. In the Hostname field, enter
192.168.100.100
as the IP address of the
DataProtection-ACM.
c. In the Port number field, specify the default port number 22.
d. In the User name field, enter
root
.
e. In the Password field, enter
Idpa_1234
.
f. Click Login.
The following figure shows a sample WinSCP session configuration window.
Hardware Installation Guide
14
Integrated Data Protection Appliance DP4400
2.4
Hardware Installation Guide