
Power requirements
Terminal block connector input
voltage/current
24 VAC (50 Hz–60 Hz) or 24 VDC /
15A
Power adapter input voltage/current
19.5 VDC / 6.67A
Battery connector port
12VDC / 15A
Environmental requirements
Ingress Protection Rating
IP50
Temperature range:
Operating (with a maximum
temperature gradation of 15°C
per hour)
• -30°C to 70°C (-22°F to 158°F)
when connected to a 24V AC/DC
power source.
• -30°C to 40°C (-22°F to 104°F)
when connected to a power
adapter or battery.
NOTE: The maximum operating
temperature is derated 1°C/
305m(1000ft) above sea level
altitude.
Non-operating
-40°C to 70 °C (-40°F to 158°F)
Relative humidity (maximum):
Operating (with maximum
humidity gradation of 10% per
hour)
10% to 90% (non-condensing)
Non-operating ((with maximum
humidity gradation of 10% per
hour)
5% to 95% (non-condensing)
Altitude (maximum, unpressurized):
Operating
-15.2m to 5000m (-50ft to 16,404ft)
NOTE: The maximum operating
temperature is derated 1°C/
305m (1000ft) above sea level
altitude.
49
Summary of Contents for Edge Gateway 5000 Series
Page 18: ...3 Tighten the screws to secure the Dell Edge Gateway to the wall 18 ...
Page 22: ...5 Close the micro SIM card tray 6 Power on your Gateway 22 ...
Page 29: ...Features 29 ...
Page 50: ...Environmental requirements Storage 15 20 m to 10 668 m 50 ft to 35 000 ft 50 ...
Page 57: ...7 Connect the intrusion switch to the Gateway 57 ...