Power requirements
Phoenix connector input voltage/
current
24 VAC (50 Hz–60 Hz) or 24 VDC /
15A
Power adapter input voltage/current
19.5 VDC / 6.67A
Battery connector port
12 VDC / 15A
Environmental requirements
Ingress Protection Rating
IP50
NOTE: Enclosure meets IP50
with the pre-installed PCIe blank
bracket. System IP rating
depends on the PCIe card IP
rating.
Temperature range:
Operating (with a maximum
temperature gradation of 15°C
per hour)
-30°C to 70°C (-22°F to 158°F)
NOTE: The maximum operating
temperature is derated 1°C/
305m(1000ft) above sea level
altitude.
NOTE: The enclosure meets this
spec without a PCIe card.
Operating temperature may
change if a PCIe card is installed.
Refer to the supported PCIe
card section for more details.
NOTE: Any component to be
assembled into the Expansion
Module shall have a still air
temperature rating that is equal
to or higher than the PCIe card
temperature rating. For without
PCIe card cases, use system
a 3C to determine the
inside air temperature.
Non-operating
-40°C to 70°C (-40°F to 158°F)