EX300 Platform
Topics:
•
•
•
•
•
•
•
•
•
Network connections between multiple ECS appliances in a single site
EX300 hardware components
The EX300 ECS appliance includes the following hardware components.
Table 15. EX300 hardware components
Component
Description
40U rack
Titan D racks that include:
●
Gen3 0U PDUs supporting single phase, three-phase delta, and three-phase WYE
●
Front and rear doors
●
Racking by Dell EMC manufacturing
In addition to the Dell EMC-racked EX300 appliance, the EX300 nodes can be installed in
customer-provided racks. For more information on third-party racking requirements, see the
ECS EX300 Third-Party Rack Installation Guide
.
Back-end (BE) switches for
private network connection
●
Two Dell EMC S5148F 25 GbE 1U ethernet switches with 48 x 25 GbE SFP ports and 6 x
100 GbE uplink ports.
●
2 x 100 GbE VLT cables per HA pair.
Front-end (FE) switches for
customer public network
connection
●
Two optional Dell EMC S5148F 25 GbE 1U ethernet switches can be obtained for network
connection or the customer can provide their own 10 GbE or 25 GbE HA pair for the front
end.
●
If the customer provides their own front-end switches, they must supply all VLT cables,
SFPs, or external connection cables.
●
If Dell EMC S5148F 25 GbE front-end switches are used, the 25 GbE ports are configured
to run at 10 GbE to connect to the EX300 nodes, and 2 x 100 GbE VLT cables are
provided.
Nodes
●
Minimum number of nodes per rack is 5 with increments of 1 node up to a maximum of 16
nodes.
●
HDD sizes can be 1TB, 2TB, 4TB, 8TB or 16TB. ECS 3.5 and later supports 16TB. (All drives
sizes must be the same in the node)
●
Within a Dell EMC manufactured rack delivered from the factory, all nodes within the rack
are of the exact same drive size. For node upgrades in the field, nodes with other sized
drives are allowed within the rack.
●
Twelve SATA hard disk drives (HDDs) in each node.
●
480GB M.2 (BOSS) system disk in each node.
●
64GB RAM per node.
●
Single Intel Xeon 8-core 85W CPU
4
EX300 Platform
47
Summary of Contents for ECS EX Series
Page 1: ...ECS EXSeries Hardware Guide 3 5 June 2021 Rev 1 2 ...
Page 15: ...Figure 6 Front end switch connections to customer switches example Switches 15 ...
Page 31: ...EX500 Platform 31 ...
Page 32: ...Figure 16 EX500 Three Phase Delta AC Cabling Diagram 32 EX500 Platform ...
Page 33: ...Figure 17 EX500 Three Phase Wye AC Cabling Diagram EX500 Platform 33 ...
Page 42: ...Figure 26 EX500 network cabling 42 EX500 Platform ...
Page 58: ...Figure 43 EX300 single phase AC power cabling 58 EX300 Platform ...
Page 59: ...Figure 44 ECSv3 740xd Single Phase AC Cabling Diagram EX300 Platform 59 ...
Page 60: ...Figure 45 Three phase Delta AC power cabling 60 EX300 Platform ...
Page 61: ...Figure 46 ECSv3 740xd Three Phase Delta AC Cabling Diagram EX300 Platform 61 ...
Page 62: ...Figure 47 Three phase WYE AC power cabling 62 EX300 Platform ...
Page 63: ...Figure 48 ECSv3 740xd Three Phase Wye AC Cabling Diagram EX300 Platform 63 ...
Page 65: ...Figure 50 iDRAC cabling EX300 Platform 65 ...
Page 71: ...Figure 57 EX300 network cabling EX300 Platform 71 ...
Page 82: ...Server front view Figure 68 EX3000 server front view in rack 82 EX3000 Platform ...
Page 91: ...Figure 78 EX3000S single phase AC power cabling EX3000 Platform 91 ...
Page 92: ...Figure 79 EX3000D single phase AC power cabling 92 EX3000 Platform ...
Page 94: ...Figure 81 EX3000S three phase delta AC power cabling 94 EX3000 Platform ...
Page 95: ...Figure 82 EX3000D three phase delta AC power cabling EX3000 Platform 95 ...
Page 96: ...Figure 83 EX3000S three phase WYE AC power cabling 96 EX3000 Platform ...
Page 97: ...Figure 84 EX3000D three phase WYE AC power cabling EX3000 Platform 97 ...
Page 101: ...Figure 86 EX3000D iDRAC cabling EX3000 Platform 101 ...
Page 108: ...Figure 94 EX3000S network cabling 108 EX3000 Platform ...
Page 109: ...Figure 95 EX3000D network cabling EX3000 Platform 109 ...
Page 112: ...Index E EX500 network cabling 35 ...