Table 3. Switch port numbers
Switch
Port number
Description
Hare
1-16
Data network ports connected to nodes (10/25 GbE)
17-40
Not designated
41-48
Customer uplink ports (10/25 GbE)
49-50
VLT ports (100 GbE)
51-54
Customer uplink ports (100 GbE)
Rabbit
1-16
Data network ports connected to nodes (10/25 GbE)
17-40
Not designated
41-48
Customer uplink ports (10/25 GbE)
49-50
VLT ports (100 GbE)
51-54
Customer uplink ports (100 GbE)
Back-end switch pair
Dell EMC provides two 25 GbE S5148F back-end switches (BE1 and BE2) with two 100 GbE VLT cables. These switches are
referred to as the Hound (BE2) and Fox (BE1) switches.
In the following diagram, all labeled ports relate to an ECS virtual data center (VDC) in which all racks/nodes are EX-Series
(Gen3 hardware), with the exception of ports 39 and 40. Ports 39 and 40 are only used in the scenario where there is Gen2
hardware series integration with EX-Series hardware in the VDC. When Gen2 hardware is mixed with EX-Series hardware, ports
39 and 40 are the only ports used for connectivity.
All iDRAC cables from nodes and all front-end switch management cable connections route to the Fox (BE1) switch.
Fox Switch (BE1)
Hound Switch (BE2)
1
48
46
44
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
4
6
2
3
5
7
9
11 13 15
17 19 21 23 25 27 29
35
31 33
37 39 41 43 45 47
1
48
46
44
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
4
6
2
3
5
7
9
11 13 15
17 19 21 23 25 27 29
35
31 33
37 39 41 43 45 47
49 51 53
49 51 53
50 52 54
50 52 54
Figure 3. Back-end switches
Table 4. Switch port number
Switch
Port number
Description
Hound
1-16
Private network ports connected to nodes (10/25 GbE)
17-40
Not designated.
41-44
In from EX-Series rack when the ECS system has more than one rack (10/25 GbE)
45-48
Out to EX-Series rack when the ECS system has more than one rack (10/25 GbE)
49-50
VLT ports (100 GbE)
51-54
Not designated (100 GbE)
12
Switches
Summary of Contents for ECS EX Series
Page 1: ...ECS EXSeries Hardware Guide 3 5 June 2021 Rev 1 2 ...
Page 15: ...Figure 6 Front end switch connections to customer switches example Switches 15 ...
Page 31: ...EX500 Platform 31 ...
Page 32: ...Figure 16 EX500 Three Phase Delta AC Cabling Diagram 32 EX500 Platform ...
Page 33: ...Figure 17 EX500 Three Phase Wye AC Cabling Diagram EX500 Platform 33 ...
Page 42: ...Figure 26 EX500 network cabling 42 EX500 Platform ...
Page 58: ...Figure 43 EX300 single phase AC power cabling 58 EX300 Platform ...
Page 59: ...Figure 44 ECSv3 740xd Single Phase AC Cabling Diagram EX300 Platform 59 ...
Page 60: ...Figure 45 Three phase Delta AC power cabling 60 EX300 Platform ...
Page 61: ...Figure 46 ECSv3 740xd Three Phase Delta AC Cabling Diagram EX300 Platform 61 ...
Page 62: ...Figure 47 Three phase WYE AC power cabling 62 EX300 Platform ...
Page 63: ...Figure 48 ECSv3 740xd Three Phase Wye AC Cabling Diagram EX300 Platform 63 ...
Page 65: ...Figure 50 iDRAC cabling EX300 Platform 65 ...
Page 71: ...Figure 57 EX300 network cabling EX300 Platform 71 ...
Page 82: ...Server front view Figure 68 EX3000 server front view in rack 82 EX3000 Platform ...
Page 91: ...Figure 78 EX3000S single phase AC power cabling EX3000 Platform 91 ...
Page 92: ...Figure 79 EX3000D single phase AC power cabling 92 EX3000 Platform ...
Page 94: ...Figure 81 EX3000S three phase delta AC power cabling 94 EX3000 Platform ...
Page 95: ...Figure 82 EX3000D three phase delta AC power cabling EX3000 Platform 95 ...
Page 96: ...Figure 83 EX3000S three phase WYE AC power cabling 96 EX3000 Platform ...
Page 97: ...Figure 84 EX3000D three phase WYE AC power cabling EX3000 Platform 97 ...
Page 101: ...Figure 86 EX3000D iDRAC cabling EX3000 Platform 101 ...
Page 108: ...Figure 94 EX3000S network cabling 108 EX3000 Platform ...
Page 109: ...Figure 95 EX3000D network cabling EX3000 Platform 109 ...
Page 112: ...Index E EX500 network cabling 35 ...