19
Dell DVS Simplified Appliance Reference Architecture
4.2.2
Drive IOPS Requirement by Workload
The next step is to determine how approximately many drives can satisfy both the
storage and the average IOPS requirement for each workload.
Standard Configuration
User Type
Drive Metrics
Drive Requirements
Basic Workload
Average IOPS per Server
129 Desktops x10 Average IOPS = 1290 IOPS
# of 10k RPM SAS Drives
1290 IOPS ÷ 150 IOPS per Disk = ~9
10k RPM SAS Drive Size
929 GB ÷ 9 = ~103GB
Standard
Workload
Average IOPS per Server
100 Desktops x12 Average IOPS = 1200 IOPS
# of 10k RPM SAS Drives
1200 IOPS ÷ 150 IOPS per Disk = ~8
10k RPM SAS Drive Size
950 GB ÷ 8 = ~119GB
Premium
Workload
Average IOPS per Server
70 Desktops x15 Average IOPS = 1050 IOPS
# of 10k RPM SAS Drives
1050 IOPS ÷ 150 IOPS per Disk = ~7
10k RPM SAS Drive Size
895 GB ÷ 7 = ~128GB
The Standard Configuration was built using 16, 300GB 10K SAS to not only satisfy these
calculations but to allow for more space for persistent and PVD desktop users as well as
to support an increase in IOPS without a dramatic increase in the price of the system.
These additional drives will also allow the array to be configured as RAID-10; thereby
adding fault tolerance to the storage array, while minimizing performance degradation.
Entry Level Configuration
User Type
Drive Metrics
Drive Requirements
Basic Workload
Average IOPS per Server
65 Desktops x10 Average IOPS = 650 IOPS
# of 10k RPM SAS Drives
650 IOPS ÷ 150 IOPS per Disk = ~5
10k RPM SAS Drive Size
545GB ÷ 5 = ~109GB
Standard
Workload
Average IOPS per Server
50 Desktops x12 Average IOPS = 600 IOPS
# of 10k RPM SAS Drives
600 IOPS ÷ 150 IOPS per Disk = ~4
10k RPM SAS Drive Size
563GB ÷ 4 = ~141GB
Premium
Workload
Average IOPS per Server
35 Desktops x15 Average IOPS = 525 IOPS
# of 10k RPM SAS Drives
525 IOPS ÷ 150 IOPS per Disk = ~4
10k RPM SAS Drive Size
546GB ÷ 4 = ~137GB
The Entry Level Configuration was built using eight 300GB 10K SAS to not only satisfy
these calculations but to allow for more space for persistent and PVD desktop users as
well as to support an increase in IOPS without a dramatic increase in the price of the
solution. These additional drives will also allow the array to be configured as RAID-10;