1. Navigate to the Network >
Fabric Name
>
Switch Name
> Troubleshoot screen. .
2. Click the SSH tab.
3. In the SSH Command field, enter the SSH command.
4. Click the Send Command button to display the SSH results.
Telnet
To issue a Telnet command on a switch:
1. Navigate to the Network >
Fabric Name
>
Switch Name
> Troubleshoot screen.
2. Click the Telnet tab.
3. In the Telnet Command field, enter the Telnet command.
4. Click the Send Command button to display the Telnet results.
Validation Alarms
To troubleshoot alarms that are generated by theAFM, use the following section.
Table 21. Validation Alarms
Alarm
Recommended Action
Validation failed because the switch cannot be
discovered.
If you have undiscovered switch errors, log on to the
switch console to isolate the fault.
NOTE: Make sure that the switch has been power
cycled on and check the physical connection.
Validation failed because the switch has a mismatch MAC
address.
1. Verify that you have correctly mapped the system
MAC address to the associated switches:
a. Navigate to the Network>
Fabric Name
>
Configure and Deploy screen.
b. From the Deploy Fabric pull-down menu, select
the Pre-deployment Configuration option.
c. Navigate to the Assign Switch Identities
screen and check the system MAC address
mapping for the associated switches.
2. Verify your change by validating the switch.
a. Navigate to the Network>
Fabric Name
>
Configure and Deploy screen.
b. From the Deploy Fabric pull-down menu, select
the Deploy and Validate option.
c. Click on the Validation tab and the check the
switch to validate.
d. Click the Validate Selected link.
Validation failed because the switch has a name
mismatch.
1. Verify that you have correctly mapped the system
MAC address to the associated switches: