Dell 2000FP LCD Monitor Service Guide
Engineering Specification
Confidential
6
(1) Mechanical Specifications
See Appendix 10 – Mechanical
(2) Cosmetic Inspection
See Appendix 10 – Mechanical
2.5.3 SHIPPING CONTAINER
See Appendix 10 – Mechanical
2.6 PALLETIZATION & SHIPMENT
See Appendix 10 – Mechanical
2.7 SERIALIZATION
See Appendix 10 – Mechanical
2.8 APPLICATION REGULATION
See Appendix 11
2.9 ENVIRONMENTAL, RELIABILITY AND OPERATING SPECIFICATIONS
Operating conditions Temperature
5 to 35
o
C
Humidity
10% to 80% (non-condensing)
Storage conditions
Temperature
0 to 60
o
C (storage) -20 to 60
o
C (shipping)
Humidity
5% to 90% (non-condensing) (storage)
5% to 95% (non-condensing) (shipping)
Appendix 0 – AC/DC power adapter
PARAMETER
RANGE
CONDITION
Input Voltage
90 to 264Vac RMS
Universal input full range
Input Frequency
47~63 Hz 90 to 264Vac
Input Current
Less than 1.7 ARMS
Input voltage 90 Vac; 60Hz.
Parameter must be reached within 3
seconds of turn-on.
Inrush Current
Less than 50A peak
Input voltage 240Vac ; 50Hz at all
phase, cold start
Input Fusing
Fuse should be located internal to the
adapter
Fuse must be UL/CUL approved.
Fuse value must no have to change
for 115 VAC operation
Leakage Current Less than 0.5mA
Input voltage 250 Vac; 50Hz
INPUT
Hi-Pot
Primary to secondary
2150Vdc for 1 Sec(leakage current
10 mA)
DC Out
19.5Vdc (18.9~20.6)
Min 0A Max 3.51A
Output Power
70Watt
Ripple & noise
500mVpp at 19.5VDC
Tested by loading side parallel with a
1uf/CC capacitors and Measured
Band-Width with DC-20MHz
Output
Short circuit
protection
The adapter can withstand continuous
short at DC output and no damage, it’ll
enter into normal condition if the fault
condition is removed.