Figure 11 DC PSU status indicator
1. DC PSU status indicator
This table describes the DC PSU status indicators and what condition is the PSU when
the power indicator light is green, blinking green, blinking amber, and when it is not lit.
Table 11 DC PSU status indicator codes
Power indicator
codes
Condition
Green
A valid power source is connected to the PSU and the PSU is
operational.
Blinking amber
Indicates a problem with the PSU.
Not illuminated
Power is not connected to the PSU.
Blinking green
When hot-plugging a PSU, the PSU indicator blinks green. This
indicates that there is a PSU mismatch with respect to efficiency,
feature set, health status, or supported voltage.
CAUTION
If two PSUs are installed, both the PSUs must have the same type
of label; for example, Extended Power Performance (EPP) label.
Mixing PSUs from previous generations servers is not supported,
even if the PSUs have the same power rating. This results in a PSU
mismatch condition or failure to turn the appliance on.
CAUTION
When correcting a PSU mismatch, replace only the PSU with the
blinking indicator. Swapping the PSU to make a matched pair can
result in an error condition and unexpected appliance shutdown.
To change from a High Output configuration to a Low Output
configuration or vice versa, you must turn off the appliance.