85 | Dell EMC VxRail Appliance Operations Guide
© 2017 Dell Inc. or its subsidiaries.
If the bezel has a key lock, lock the bezel with the provided key and store the key in a
secure place.
10. On the VxRail Manager, Health page, Physical view, verify that the drive shows a Healthy
status. Refresh the page if necessary.
11. Log into vCenter and perform a vSAN health check.
a. In the navigation panel, select the vSAN cluster.
b. In the Monitor tab, select
Virtual SAN
>
Health.
c. Click
Retest
.
d. Verify that there are no errors.
Replacing a power supply
A VxRail Appliance has redundant hot-swappable power supplies. You can remove a faulty
Power Supply Unit (PSU) and insert a new one without having to shut down the node.
Procedure
The following procedure lists the high-level steps involved to replace a capacity drive.
For more detailed procedures for specific hardware configurations, see the procedure generated
from the SolVe Desktop available from Dell EMC support
https://support.emc.com/
.
1. On the VxRail Manager Health, Physical view, identify the failed component.
2. Disconnect the power cable from the power source and from the PSU.
3. Press the release latch and slide the power supply unit out of the chassis.
4. Slide the new power supply unit into the chassis until the power supply unit is fully seated
and the release latch snaps into place.
5. Connect the power cable to the power supply unit and plug the cable into a power outlet.
The system takes approximately 15 seconds to recognize the power supply unit and
determine its status. The power supply status LED turns green signifying that it is working
properly.
6. On the VxRail Manager,
Health
page,
Physical
view, verify that the error is resolved and
the PSU shows a Healthy status. Refresh the page the page if needed.
Summary of Contents for VxRail Appliance
Page 86: ......