Expanded operating
temperature
Specifications
For temperatures between 35°C-40°C, derate maximum allowable temperature by 1°C per 175 m
above 950 m (1°F per 319 ft).
≤ 1% of annual operating hours
–5°C–45°C at 5% to 90% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature (10–35°C), the system can operate
down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours.
For temperatures 40°C–45°C, derate maximum allowable temperature by 1°C per 125 m above 950
m (1°F per 228 ft).
NOTE:
When operating in the expanded temperature range, system performance may be impacted.
NOTE:
When operating in the expanded temperature range, ambient temperature warnings may be reported in the System Event
Log.
Expanded operating temperature restrictions
•
Do not perform a cold startup below 5°C.
•
The operating temperature specified is for a maximum altitude of 3048 m (10,000 ft).
•
Two nonredundant power supply units are required.
•
Two nonredundant system fans are required.
•
Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
•
GPU is not supported.
•
Tape backup unit is not supported.
Thermal restriction matrix
Table 26. Thermal restriction matrix for Dell EMC PowerEdge T440 system
Storage configuration
4x 3.5-inch cable
drive
8x 3.5-inch drive
16x 2.5-inch drive
Processor number
TDP (W)
Core count
Ambient support = 35°C
Intel Xeon Gold 5122
105
4
Yes
Yes
Yes
Intel Xeon Platinum
8156
105
4
Yes
Yes
Yes
Intel Xeon Gold 5120
105
14
Yes
Yes
Yes
Intel Xeon Gold 5118
105
12
Yes
Yes
Yes
Intel Xeon Gold 5115
85
10
Yes
Yes
Yes
Intel Xeon Silver 4116 85
12
Yes
Yes
Yes
Intel Xeon Silver 4114 85
10
Yes
Yes
Yes
Intel Xeon Silver 4110 85
8
Yes
Yes
Yes
Intel Xeon Silver
4108
85
8
Yes
Yes
Yes
Technical specifications