Figure 91. Installing a power supply unit blank
Installing a power supply unit
Prerequisites
1. Follow the safety guidelines listed in the
.
2. For systems that support redundant PSU, ensure that both the PSUs are of the same type and have the same maximum
output power.
NOTE:
The maximum output power (shown in watts) is listed on the PSU label.
3. Remove the PSU blank.
Steps
Slide the PSU into the PSU bay until the release latch snaps into place.
NOTE:
The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 92. Installing a power supply unit
Next steps
1. If you have unlatched the cable management arm, relatch it. For information about the cable management arm, see the
system’s rack documentation at
https://www.dell.com/poweredgemanuals
.
2. Connect the power cable to the PSU, and plug the cable into a power outlet.
Installing and removing system components
91