13
Versa Drawer Refrigeration Units
ELECTRIC INPUT/OUTPUT (I/O)
CONTROL BOARD
CAUTION
ELECTROSTATIC SENSITIVE ASSEMBLY; USE
PRECAUTIONARY PROCEDURES WHEN HANDLING
CIRCUIT CARD ASSEMBLIES.
1. Disconnect power from the refrigeration unit.
2. Remove the front louvered panel as described in
COVERS AND PANELS.
3. Remove the louvered access end panel as described
in COVERS AND PANELS.
NOTE:
The electric input/output (I/O) control
board is mounted on the inside top of
the machine compartment.
4. Tag and disconnect the wiring harness from the
electric I/O control board (Figure 16).
5. Remove four screws securing the electric I/O control
board to the machine compartment.
6. Remove the electric I/O control board from the
refrigeration unit.
7. Reverse the above steps to install a replacement
electric I/O control board.
LEGS
DANGER
Use a jack to lift the refrigeration unit off the ground
just far enough to remove the leg. Place blocking
underneath the refrigeration unit. Do not work
underneath a raised unit without proper blocking. Do
not lift the unit more than necessary to remove the
leg. Lifting the unit too far can make the unit unstable.
1. Place a jack underneath the refrigeration unit as close
as possible to the leg (Figure 16). Lift the unit just high
enough to remove the leg from underneath the
refrigeration unit. Place blocking underneath the unit to
prevent the unit from falling during removal of the leg.
2. Remove four screws from the upper portion of the leg.
3. Remove the leg from the refrigeration unit.
4. Reverse the above steps to install a replacement leg.
Screws
Figure 16. Leg Removal
CASTERS
DANGER
Use a jack to lift the refrigeration unit off the
ground just far enough to remove the leg. Place
blocking underneath the refrigeration unit. Do
not work underneath a raised unit without proper
blocking. Do not lift the unit more than necessary
to remove the caster. Lifting the unit too far can
make the unit unstable.
1. Place a jack underneath the refrigeration unit as
close as possible to the caster (Figure 17). Lift the
unit up just high enough to remove the caster from
underneath the refrigeration unit. Place blocking
underneath the unit to prevent the unit from falling
during removal of the caster.
2. Remove four screws from the upper portion of the caster.
3. Remove the caster from the refrigeration unit.
4. Reverse the above steps to install a replacement caster.
Screws
Figure 17. Caster Removal