24
Delfield
Programming
Three buttons are used for the programming: SET, UP
and DOWN buttons. See Figure 7.
NOTE:
By lifting the gray plastic cover, but-
tons will be exposed.
1.
Scroll through the parameters using the UP and
DOWN arrow keys.
2.
Choose the parameter to be changed by press-
ing SET.
3.
Scrolling through the options or set the time or
temperature by using the UP and DOWN arrow
keys.
4.
Once you choose the option or adjust the time
or temperature, press SET to accept the option.
The ERC-2 control initially powers up displaying 12AM,
otherwise it will show the last configured selection (time
or temperature). If a power outage occurs during normal
operation, the control will maintain the correct time of day
using a capacitor (batteries are not required). The time
will be maintained for up to 100 hours when the capacitor
is fully charged.
To initiate a Manual Defrost, press and hold the MAN
DEF key for 3 seconds.There are two levels of program-
ming in the ERC-2. The first of security will enable the
user to set two parameters: Time-of-day (CLoC and
setpoint temperature SET). The other level allows ac-
cess to the other parameters.
Figure 7. ERC Control Panel
For more information on the ERC Control, please log onto
our web site at www.delfield.com and go to the parts and
service section, then to the service department page.
STEP 1
SET
Press and hold SET for 5 seconds. The display will show CLoC
STEP 2
SET
Press SET again to change the time of day.
STEP 3
UP OR DOWN
Press UP or DOWN until the correct time of day is displayed.
STEP 4
SET
Press SET to accept the new time.
STEP 5
DOWN
Press DOWN to go to the next parameter. - Set point temperature -
SEt (cut out).
STEP 6
SET
Press SET to change the set point temperature.
STEP 7
UP OR DOWN
Press UP or DOWN to go to the desired setpoint. The range is -40°F
(-40°C) to 60°F (16°C.).
STEP 8
SET
Press SET to accept the change.
STEP 9
DOWN
Press DOWN to exit the first level of programming.
NOTE:
During programming, if no button is pushed during a 30 seconds interval, the control will go back
to the normal operating mode. This is valid for both programming levels.
NOTE:
When changing the time, press and hold the MAN DEF button for 3 seconds to change the AM/PM
mode.