background image

Part Number: 9291472  05/18 

5

Section 2 

Installation

Dimensions

Model

Length

Depth

Height

EHEI36

36.00”  

(91cm)

31.50”  

(80cm)

36.00” 

 (91cm)

EHEI48

48.00” 

(122cm)

31.50”  

(80cm)

36.00”  

(91cm)

EHEI60

60.00” 

(152cm)

31.50” 

 (80cm)

36.00” 

 (91cm)

EHEI74

74.00” 

(188cm)

31.50”  

(80cm)

36.00”  

(91cm)

Capacity

Model

Number of 11.87” x 19.87”  

(30.2cm x 50.5cm) openings

EHEI36

2

EHEI48

3

EHEI60

4

EHEI74

5

Electrical Service

 DANGER

Check all wiring connections, including factory terminals, 

before operation. Connections can become loose during 

shipment and installation.

n

Warning

This appliance must be grounded and all field wiring must 

conform to all applicable local and national codes. Refer 

to rating plate for proper voltage. It is the responsibility of 

the end user to provide the disconnect means to satisfy 

the authority having jurisdiction.

All electrical work, including wire routing and grounding, 

must conform to local, state and national electrical codes.
The following precautions must be observed:
•  The equipment must be grounded.
•  A separate fuse/circuit breaker must be provided for each 

unit.

•  A qualified electrician must determine proper wire size 

dependent upon location, materials used and length of 

run (minimum circuit ampacity can be used to help select 

the wire size).

•  The maximum allowable voltage variation is ±10% of the 

rated voltage at equipment start-up (when the electrical 

load is highest).

•  Check all green ground screws, cables and wire 

connections to verify they are tight before start-up.

Model

Voltage, Cycle, 

Phase

Amps

Plug

Watts

EHEI36C

120, 60, 1

20.0

Hard wired

-

EHEI36C-E

240, 50, 1

-

CEE 7/7

2900

EHEI36L

120, 60, 1

20.0

5-30P

-

EHEI36L-E

240, 50, 1

-

CEE 7/7

2900

EHEI48C

208/230, 60, 1 15.0/16.0

Hard wired

-

EHEI48C-E

240, 50, 1

-

CEE 7/7

4350

EHEI48L

208/230, 60, 1 15.0/16.0

6-20P

-

EHEI48L-E

240, 50, 1

-

CEE 7/7

4350

EHEI60C

208/230, 60, 1 20.0/22.0

Hard wired

-

EHEI60C-E

240, 50, 1

-

CEE 7/7

5800

EHEI60L

208/230, 60, 1 20.0/22.0

6-30P

-

EHEI60L-E

240, 50, 1

-

CEE 7/7

5800

EHEI74C

208/230, 60, 1 24.0/27.0

Hard wired

-

EHEI74C-E

240, 50, 1

-

CEE 7/7

7250

EHEI74L

208/230, 60, 1 24.0/27.0

6-50P

-

EHEI74L-E

240, 50, 1

-

CEE 7/7

7250

Leg Leveling

All four legs are adjustable. Adjust each leg until the unit 

is stable and level, both front to back and left to right. A 

level unit is necessary to maintain an equal water depth 

throughout the wells.

Plumbing

n

Warning

Moisture collecting from improper drainage can create a 

slippery surface on the floor and a hazard to employees. 

It is the owner’s responsibility to provide a container or 

outlet for drainage.

A waste connection is provided 26.5” (67cm) above the 

floor, 5.25” (13cm) from the right end. You must supply the 

required 1/2” (1.3cm) connection at the gate valve.

Summary of Contents for E-Chef EHEI36C

Page 1: ...nstructions Installation Operation and Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual Part Number 9291472 05 18 E Chef Hot Food Table ...

Page 2: ...certified by 3 Export E Models are certified by 3 Model Numbers 3 Section 2 Installation Location 4 Weight of Equipment 4 Clearance Requirements 4 Dimensions 5 Capacity 5 Leg Leveling 5 Plumbing 5 Section 3 Operation Wet operation 6 Dry operation 6 Temperature 6 Section 4 Maintenance General 7 Stainless Steel Cleaning 7 Food Wells 7 Drain 7 Table of Contents ...

Page 3: ...fornia to cause birth defects or other reproductive harm nWarning This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision concerning use of the appliance by a person responsible for their safety Do not allow children to play with this appliance Notic Proper ...

Page 4: ...lected for the equipment must meet the following criteria If any of these criteria are not met select another location Units are intended for indoor use only The location MUST be level stable and capable of supporting the weight of the equipment The location MUST be free from and clear of combustible materials Do not install near objects or surfaces affected by heat or moisture Equipment MUST be l...

Page 5: ... the wire size The maximum allowable voltage variation is 10 of the rated voltage at equipment start up when the electrical load is highest Check all green ground screws cables and wire connections to verify they are tight before start up Model Voltage Cycle Phase Amps Plug Watts EHEI36C 120 60 1 20 0 Hard wired EHEI36C E 240 50 1 CEE 7 7 2900 EHEI36L 120 60 1 20 0 5 30P EHEI36L E 240 50 1 CEE 7 7...

Page 6: ...e to the well over time Before the unit is used the first time turn the temperature knob to HI and heat the well for up to 30 minutes Any residue or dust that adhered to the heater element s will be burned off during this initial preheat period NOTE Never place food directly into the well Always use pans Although these models may be operated either with or without water in the wells wet operation ...

Page 7: ...ed by the warranty Stainless Steel Cleaning Clean the unit and around it as often as necessary to maintain cleanliness and efficient operation Wipe surfaces with a damp cloth rinsed in water to remove dust and dirt from the unit Always rub with the grain of the stainless steel to avoid marring the finish If a greasy residue persists use a damp cloth rinsed in a mild dish soap and water solution Wi...

Page 8: ...8 Welbilt provides the world s top chefs and premier chain operators or growing independents with industry leading equipment and solutions Our cutting edge designs and lean manufacturing tactics are powered by deep knowledge operator insights and culinary expertise All of our products are backed by KitchenCare our aftermarket repair and parts service CLEVELAND CONVOTHERM DELFIELD FITKITCHEN FRYMAS...

Reviews: