Trouble shooting
Section 6
36
Part Number: 9291000 06/22
Parem.
Label Description
Min
Max
Default
U.M.
Type
CC7
Compressor On time (in negative storage) in case of cabinet
probe error
0
99
8
min
CC8
Pump down duration
0
999
0
sec
CC9
Reading the tens of hours of compressor operation (for
preventive maintenance)
0
999
0
tens of
hours
CCA
Compressor maintenance hours
0
9990
9990
hours
Defrosting
D0
Defrosting interval (0 = does not defrost)
0
99
8
hours
User
D1
Type of defrosting (0 = Resistances / 1 = hot gas (if CC4=0) / 2
= air)
0
2
1
Flag
D2
End defrosting set-point (referred to the evaporator probe)
with fixed hysteresis of 45°F or 7°C
-50
90
2
°C
D3
Max defrosting duration
1
99
20
min
D4
Defrosting at the beginning of the chilling/freezing
(0=No/1=Yes)
0
1
0
Flag
D5
1st defrosting activation delay after a chilling (if D5 = 0, the
first defrosting is performed after D0)
0
999
99
min
D7
Drip time
0
9
2
min
D9
Ignore compressor delays at the beginning of the defrosting;
0=enabled, 1=disabled)
0
1
1
Flag
DA
Evaporator probe reading (ready only)
--
--
--
°C
User
DC
Hot has valve delay - compressor during defrosting
0
99
5
sec
DD
Temp threshold X frame resistance activation Without
running cycles, it will be turned off
0
90
0
°C
DE
Hysteresis for door resistance management
1
10
2
°C
Fan Adjustment
F2
Set point above which the evaporator fans can be activated
during chilling/freezing (if evap probe present /5=1)
-50
90
35
°C
F3
Fans stopped with the compressor stopped (0=No, 1=Yes) -
valid only in storage
0
1
1
flag
F4
Stop fans during defrosting (0=no, 1=yes) (this parameter
has an impact on the air defrosting)
0
1
1
flag
F5
Fan stop time after dripping
0
9
3
min
F7
Set temperature (cabinet probe) High temp (above this value,
the evap fans are not activated)
-50
90
70
°C
F8
Differential x parameter F7
1
10
5
°C
F9
Condenser fan turn off delay time and forced output
activation time
0
99
20
sec
Various
U1
Door opening effect on evaporator ventilation (0=no effect,
1=Block ventilation) - except for the drying phase
0
1
1
flag
U2
Micro door SW1 input polarity (0=N.O., 1=N.C.)
0
1
1
flag
U4
High pressure alarm delay
0
999
5
sec
Summary of Contents for CV10E
Page 3: ...THIS PAGE INTENTIONALLY LEFT BLANK Part Number 9291000 06 22 3 ...
Page 11: ...THIS PAGE INTENTIONALLY LEFT BLANK Section 2 Specifications Part Number 929100 06 22 11 ...
Page 17: ...Section 3 Installation Part Number 9291000 06 22 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 25: ...Section 4 Operation Part Number 9291000 06 22 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 39: ...Section 6 Trouble shooting Part Number 9291000 06 22 39 ...