Operation
Section 4
24
Part Number: 9291000 06/22
recalling of 99 chilling cycles.
To store a chilling cycle the user must:
1) set a chilling type (button 1 - 2)
2) set the mode of chilling (by temperature or by time,
button (5))
3) set the total time or the final tempe/- buttons.
4) press and hold (long press) the “PROGRAM” button (16)
until the beeper emits a beep; the LED of the button starts
to flash. On the basis of the first display it will flash signifying
waiting for setting of the first letter/number.
5) then using the keys +/- set the first letter/number and
confirm with the button (5). This will confirm the value,
passing on to the next one. Arriving at the ninth character or
even before, it is possible to press the START button for start
and storage (ATTENTION, if a program with the same name
already exists, it will be overwritten.)
6) press START/STP (22)
With Start the software stores the “type” and “mode” of the
chilling selected.
To discontinue saving of the program, press the storage
button again or wait for the TimeOut (approximately 10
seconds). If time chilling has been set, the duration set is
stored.
In the case of temperature chilling, it will store the time in
which the insert probe reaches the PRODUCT TEMPERATURE
SET, and will store this time as duration of chilling.
In addition, if the chilling is Positive Hard, it also saves the
time necessary to reach the core at 68°F (20°C) (Hard).
When saving a temperature (insert probe) chilling cycle,
the LED of the programming button flashes to indicate
that storage of the times is in progress. As soon as the
temperature chilling cycle ends, the LED stops flashing to
indicate that storage has been successful.
If storing a temperature cycle, this stops (due to alarms,
button stop, etc.), the cycle times are not saved. The initial
settings however remain saved.
Chilling Program Execution
To call up and run a memory-resident program, the user must:
1) press the “PROG” button (short press), the LED lights up
and with the +/- buttons, select one of the saved programs.
2) press START
If the save button is pressed by accident, pressing it again
will exit that function.
While a program is running, by pressing the “PROG” button
the display shows the name of the program in progress.
Summary of Contents for CV10E
Page 3: ...THIS PAGE INTENTIONALLY LEFT BLANK Part Number 9291000 06 22 3 ...
Page 11: ...THIS PAGE INTENTIONALLY LEFT BLANK Section 2 Specifications Part Number 929100 06 22 11 ...
Page 17: ...Section 3 Installation Part Number 9291000 06 22 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 25: ...Section 4 Operation Part Number 9291000 06 22 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 39: ...Section 6 Trouble shooting Part Number 9291000 06 22 39 ...