Section 6
Trouble shooting
Part Number: 9291000 06/22 35
Parem.
Label Description
Min
Max
Default
U.M.
Type
C1
Chilling duration by time and max chilling by temperature
0
400
90
min
User
C2
Set chilling end (higher between the two probes)
C2A
C2B
3
°C
User
C2A
Min. product temp for chilling by temperature
-50
C2B
1
°C
C2B
Max. product temp for chilling by temperature
C2A
90
10
°C
C3
Set positive storage (referred to the cabinet probe)
-50
90
2
°C
User
C4
During the freezing by time and max. duration provided
for the freezing by temp. (with C4=0, then the freezing key
and function equal to 0°F, or -18°C, will be disabled. Only for
positive blast chilling)
0
400
240
min
User
C5
Set freezing end (referred to the needle probe with higher T°)
C5A
C5B
-25
°C
C5A
Min. product temp for freezing by temp.
-50
C5B
-25
°C
C5B
Max. product temp for freezing by temp
C5A
90
-5
°C
C6
Set negative storage (referred to the cabinet probe)
-50
90
-25
°C
User
C7
Needle test threshold
0
99
5
°C
C8
Start temp for counting the chilling and freezing duration
(above that value, the counting will start)
-50
90
65
°C
C9
Acoustic signal activation time at the end of the chilling
0
99
60
sec
User
CA
Needle 1 probe reading (read only)
--
--
--
°C
User
CA1
Needle 2 probe reading (read only)
--
--
--
°C
User
CB1
Set cabinet in SOFT+SOFT chilling (cabinet probe)
-50
90
-3
°C
CB2
Set cabinet in SOFT chilling (cabinet probe) and second
phase of HARD chilling
-50
90
-5
°C
CC
Set cabinet in freezing (cabinet probe)
-50
90
-40
°C
CD
Set HARD end (HARD to SOFT, needle probe temperature)
-50
90
20
°C
CE
Duration of differential test X verification of probe insertion
(needle test time)
0
99
0
sec
CF
Set cabinet during the first HARD chilling phase (cabinet
probe)
-50
90
-20
°C
CS
Set second cabinet for the negative SOFT cycle phase
-50
90
-30
°C
Ice Cream
T0
Ice cream hardening duration
1
400
10
min
User
TH
Positive cycle hard phase percentage
1
100
35
%
TS
Negative cycle soft phase percentage
1
100
30
%
Compressor Protection
CC0
Compressor start delay upon turning on the tool
0
9
2
min
CC2
Min compressor pause
0
99
3
min
CC4
2nd compressor activation delay (with CC4=0 K3 output as
liquid solenoid valve, otherwise K3 output as 2nd compressor,
it is not possible to activate the defrost with HOT GAS)
0
9
0
sec
CC5
Compressor cycle time (On + Off) in case of cabinet probe
error
0
99
10
min
CC6
Compressor On time (in positive storage) in case of cabinet
probe error
0
99
3
min
Summary of Contents for CV10E
Page 3: ...THIS PAGE INTENTIONALLY LEFT BLANK Part Number 9291000 06 22 3 ...
Page 11: ...THIS PAGE INTENTIONALLY LEFT BLANK Section 2 Specifications Part Number 929100 06 22 11 ...
Page 17: ...Section 3 Installation Part Number 9291000 06 22 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 25: ...Section 4 Operation Part Number 9291000 06 22 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 39: ...Section 6 Trouble shooting Part Number 9291000 06 22 39 ...