background image

15

Compact Refrigerators

 

The electronic temperature control constantly monitors 

box temperature as well as evaporator coil temperature to 

maintain consistent product temperatures.
At initial start-up or anytime power is disconnected, then 

reconnected to the unit, the control will delay all operations 

for a short time (up to 10 minutes.)  While in this delay period, 

the control initializes the control parameters and confirms 

that the temperature sensors and circuits are operational.

REGARDING FREEZERS:  After initializing, the 

control will immediately enter a DEFROST mode.  

The compressor and condenser fan as well as the 

evaporator fan will remain off until initialization 

defrost is complete.  This initial defrost cycle may 

take up to 15 minutes to complete, at which time 

the freezing cycle will begin.

The control is located in the rear of the cabinet. Freezers 

are factory set at mid-range to maintain about -3ºF  

(-19ºC) box temperature. To adjust for colder temperatures, 

turn the knob clockwise.  For warmer temperatures, turn 

the knob counter-clockwise.  Turn the knob fully counter-

clockwise to turn the refrigeration system off.  Never turn 

the knob more than 1 dial number and always allow 8 hours 

for temperature stabilization before making any additional 

adjustments.
Freezer cabinets with two evaporators have counter-rotating 

fans to ensure even airflow throughout the cabinet. The left 

evaporator has a CCW motor and a clear fan blade and the 

right evaporator has a CW motor and a black fan blade.
The evaporator fan(s) and condenser fan will cycle off and on 

with the compressor to conserve energy.

Freezer:

Whenever the freezer is plugged in, and the control has 

completed initializing including the initial defrost cycle.  

The temperature control will cycle the compressor and 

condenser fan motor and evaporator fan motor to maintain 

box temperature at the control setting.

Freezer Automatic Defrost

The control also monitors compressor total running time 

and will enter a defrost cycle after total compressor running 

time is greater than 4-hours since the last defrost cycle OR 

if evaporator coil temperature drops below -34ºF (-37ºC) 

(indicating excessive frost on the coil.)
When the control enters the defrost mode, it switches off the 

evaporator fan motor, compressor and condenser fan motor, 

and switches on the defrost heater to warm the evaporator 

coil. Thereby melting all frost accumulated during the previous 

refrigeration cycle.  The control will continue the defrost 

cycle for a MINIMUM  of 8 minutes and a MAXIMUM of 30 

minutes depending on the amount of frost accumulated on 

the evaporator coil.
After the defrost cycle is complete, the control returns to a 

normal refrigeration cycle, however the evaporator fan motor 

will not switch on for 2 minutes AFTER the compressor and 

condenser fan motor have begun operating. 

Freezer Manual Defrost

If a manual defrost is desired, simply unplug the unit for several 

seconds, then plug unit back in.  This will cause the control 

to re-initialize and then enter a defrost cycle.

Service Alert

During normal operation the evaporator fan may cycle 

and/or pulse independently of the compressor. Consult 

the service manual or contact Technical Support at 

1-800-733-8829 if you are unsure of the proper function.

Freezer Cabinet Operation

Cooling Cycle

Defrost Cycle

Compressor On Compressor Off Compressor Off

Evap 

Fan On

Evap 

Fan Off

Evap 

Fan On

Evap 

Fan Off

Evap 

Fan On

Evap 

Fan Off

4500 

Freezer

X

X

X

Freezers

Temperature Control Knob Access

Summary of Contents for 4427N

Page 1: ...829 Fax 989 773 3210 www delfield com Installation Operation Manual 4400 Series Compact Refrigerators 4500 Series Compact Freezers Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately 9294098 ...

Page 2: ...e Unless They Have Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety WARNING This Appliance Is Not To Be Played With Warning Do Not Clean With Water Jet WARNING Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This Appliance CAUTION Observe the following Minimum clearances must be maintained from all walls and comb...

Page 3: ...ing material until an inspection has been made or waived 9 Do not use forklift or pallet jack to move this equipment once it is removed from the pallet Doing so may cause equipment damage and void warranty Uncrating the Equipment First cut and remove the banding from around the crate Remove the front of the crate material use of some tools will be required If the unit is on legs remove the top of ...

Page 4: ...ield com This manual covers standard cabinets only If you have a custom cabinet consult the customer service department at 800 733 8829 2013 The Delfield Company All rights reserved Reproduction without written permission is prohibited Delfield is a registered trademark of The Delfield Company Introduction Regulatory Certifications Models are certified by National Sanitation Foundation NSF Underwr...

Page 5: ...9 5 15P 245 ST4427N one door 27 31 5 36 8 20 3 17 1 5 7 0 3 9 5 15P 223 STD4427N two drawer 27 31 5 36 8 20 1 5 7 0 3 9 5 15P 245 4432N one door 32 31 5 36 10 10 3 88 1 5 7 0 3 9 5 15P 245 D4432N two drawer 32 31 5 36 10 10 1 5 7 0 3 9 5 15P 293 ST4432N one door 32 31 5 36 10 10 3 88 1 5 7 0 3 9 5 15P 245 STD4432N two drawer 32 31 5 36 10 10 1 5 7 0 3 9 5 15P 293 4448N two door 48 31 5 36 16 00 5 ...

Page 6: ...5 15P 411 STD4460N 8 four drawer 60 31 5 36 20 20 8 1 2 11 12 5 15P 495 4464N 8 two door 64 31 5 36 21 60 7 76 8 1 2 11 12 5 15P 421 D4464N 8 four drawer 64 31 5 36 21 60 8 1 2 11 12 5 15P 522 4464N 12 two door 64 31 5 36 21 60 7 76 12 1 2 11 12 5 15P 421 D4464N 12 four drawer 64 31 5 36 21 60 12 1 2 11 12 5 15P 522 4464N 16 two door 64 31 5 36 21 60 7 76 16 1 2 11 12 5 15P 421 D4464N 16 four draw...

Page 7: ... 5 15P 495 ST4460N 18M two door 60 31 5 36 20 20 7 19 18 1 2 11 12 5 15P 411 STD4460N 18M four drawer 60 31 5 36 20 20 18 1 2 11 12 5 15P 495 4464N 12M two door 64 31 5 36 21 60 7 76 12 1 2 11 12 5 15P 421 D4464N 12M four drawer 64 31 5 36 21 60 12 1 2 11 12 5 15P 522 4464N 18M two door 64 31 5 36 21 60 7 76 18 1 2 11 12 5 15P 421 D4464N 18M four drawer 64 31 5 36 21 60 18 1 2 11 12 5 15P 522 4464...

Page 8: ... 60 31 5 34 25 20 20 8 1 2 11 12 5 15P 495 UC4460N 12 two door 60 31 5 34 25 20 20 7 19 12 1 2 11 12 5 15P 411 UCD4460N 12 four drawer 60 31 5 34 25 20 20 12 1 2 11 12 5 15P 495 UC4464N 8 two door 64 31 5 34 25 21 60 7 76 8 1 2 11 12 5 15P 421 UCD4464N 8 four drawer 64 31 5 34 25 21 60 8 1 2 11 12 5 15P 522 UC4464N 12 two door 64 31 5 34 25 21 60 7 76 12 1 2 11 12 5 15P 421 UCD4464N 12 four drawer...

Page 9: ... 31 5 34 25 20 20 7 19 18 1 2 11 12 5 15P 411 UCD4460N 18M four drawer 60 31 5 34 25 20 20 18 1 2 11 12 5 15P 495 UC4460N 24M two door 60 31 5 34 25 20 20 7 19 24 1 2 11 12 5 15P 411 UCD4460N 24M four drawer 60 31 5 34 25 20 20 24 1 2 11 12 5 15P 495 UC4464N 12M two door 64 31 5 34 25 21 60 7 76 12 1 2 11 12 5 15P 421 UCD4464N 12M four drawer 64 31 5 34 25 21 60 12 1 2 11 12 5 15P 522 UC4464N 18M ...

Page 10: ...15P 293lbs 133kg 4560N two door 60 152 4cm 31 5 80 0cm 36 91 4cm 16 90 7 19 1 3 14 0 12 0 5 15P 411lbs 186kg ST4560N two door 60 152 4cm 31 5 80 0cm 36 91 4cm 16 90 7 19 1 3 14 0 12 0 5 15P 411lbs 186kg ST prefix models have a 4 stainless steel backsplash Undercounter freezers Model Description L D Work H Volume Ft 3 Shelves Ft 2 H P Refg Charge Amp NEMA Plug Ship Weight UC4532N one door 32 81 3cm...

Page 11: ...n is the owner s and operator s responsibility Plumbing Self contained models are standard with a condensate evaporator If for some reason a cabinet does not have a condensate evaporator or the evaporator fails the cabinets drain must have an outlet to an appropriate drainage area or container Moisture collecting from improper drainage can createaslipperysurfaceonthefloorandahazard to employees It...

Page 12: ...upports Changing Pan Height If additional pan temperature cooling ability is desired especially in higher ambient temperature conditions and or if pan covers are open or off for extended time periods improvedcoolingofpanscanusuallybeachievedbyutilizing the lower position of the dual level pan guides When utilizing the lower position on a model with drawers only 4 deep pans can be used in the top W...

Page 13: ... located in rear of cabinet controls the temperatureinsidethebox Thefactorysettingforthecontrol is 4 5 and maintains about 34 F 1 C to 36 F 2 C inside the box Settoward1forhighertemperaturesandsettoahigher number for lower temperatures Evaporator Fan s Operation Salad and mega top refrigerator units under 60 wide have one evaporator and one evaporator fan motor and blade 60 64 and 72 wide units ha...

Page 14: ...en the controller enters the defrost mode the compressorisshutoffandwillremainoffuntiltheevaporator coiltemperatureexceeds41 Forthecontrollerreachesatime limitof50minutes Thedefrostcyclecanlastfromaminimum of 2 minutes to a maximum of 50 minutes Service Alert During normal operation the evaporator fan may cycle and or pulse independently of the compressor Consult the service manual or contact Tech...

Page 15: ...ol has completed initializing including the initial defrost cycle The temperature control will cycle the compressor and condenser fan motor and evaporator fan motor to maintain box temperature at the control setting Freezer Automatic Defrost The control also monitors compressor total running time and will enter a defrost cycle after total compressor running time is greater than 4 hours since the l...

Page 16: ...d other vegetables CLEANING THE CONDENSER COIL The condenser coil requires regular cleaning every 90 days recommended In some instances you may find a large amountofdebrisanddustorgreaseaccumulatedpriortothe 90 day time frame In these cases the condenser coil should be cleaned every 30 days Ifthebuilduponthecoilconsistsofonlylightdustanddebris thecondensercoilcanbecleanedwithasimplebrush Heavier d...

Page 17: ...sink with detergents and a soft bristle brush Drawers and tracks should be cleaned on a weekly basis Remove Drawers Pull the drawer box out until it stops Lift up on the drawer front andpullthedrawerboxcompletelyout Usingasoftbristlebrush clean the track on the bottom of the drawer box When finished it should be wiped clean of all food and debris Tracks The drawer box assembly must be removed Pull...

Page 18: ... G BLACK NEMA 5 15P Supply Cord and Plug furnished EVAPORATOR FAN TEMPERATURE CONTROL CONDENSING UNIT WHITE N HPS Wiring Diagram 4427 Flat Top Refrigerator Wiring Diagram All Remaining Flat Top Refrigerators 9294473 ...

Page 19: ...reezers NEMA 5 15P Supply Cord and Plug furnished L1 TEMPERATURE CONTROL HPS N 1 3 5 EVAPORATOR FANS POWER SWITCH Select models only CONDENSING UNIT Wiring Diagram Salad Mega Top Refrigerators Temperature Control Knob Access Power Switch Access 4460 4464 4472 Salad and Mega top models ...

Page 20: ...r with the service claim LABOR OF 1 HOUR IS ALLOWED TO REPLACE Thermostat Evaporator Condenser Fan Motor and Blade Hi limit Thermal Protector Switch Door Hinges Locks and Gaskets Compressor Start Components and Overload Protector LABOR OF 2 HOURS IS ALLOWED TO REPLACE Drawer Tracks Cartridges Locate Repair a Leak Defrost Heater LABOR OF 3 HOURS IS ALLOWED TO REPLACE Condenser or Evaporator Coil Ho...

Page 21: ...21 Compact Refrigerators Notes ...

Page 22: ...22 Delfield Notes ...

Page 23: ...23 Compact Refrigerators Notes ...

Page 24: ...u for choosing Delfield Help is a phone call away Help our team of professional courteous customer service reps by having your model number and serial number available at the time of your call 800 733 8829 Model ________________________ S N _______________________ Installation Date ________________ For a list of Delfield s authorized parts depots visit our website at www delfield com Register your...

Reviews: