Compact Refrigerators

 

Power Switch

Salad and Mega top 4460, 4464, and 4472 models are equipped 

with a power disconnect switch located at the rear of the unit 

just below the thermostat control knob. Switch must be in 

the “on” position for the unit to operate. 

Operation

After the cabinet is connected to the power source it will 

automatically begin operating. With the covers and doors 

closed, the temperature of the cabinet should reach 36°F to 

40°F (2°C to 4°C) in about one hour. Temperature on salad 

top will maintain 33°F to 41°F (1°C to 4°C) with pans recessed 

2.5” (6.5cm) at 86°F ambient room temperature for a period 

of four hours, meeting NSF-7 requirements. The temperature 

control on a flat top unit other than 4427 models is located 

on the back panel inside the refrigerator and can be adjusted 

to meet the current conditions. The temperature control on 

4427 flat top and all salad top units is located in the rear of 

the unit, 14" to 16" above floor in access hole.

Temperature Control Instruction for Flat Top Units 

except 4427 Models

A thermostat located in the evaporator housing on the interior 

rear of the cabinet controls the temperature inside the box. The 

factory setting for the control is “4” and maintains about 38°F 

(3°C) inside the box. Set toward “1” for higher temperatures 

and set to a higher number for lower temperatures. 

Temperature Control Instruction for Salad Top 

Units and 4427 Flat Top Models

A thermostat located in rear of cabinet controls the 

temperature inside the box. The factory setting for the control 

is 4.5 and maintains about 34°F(1°C) to 36°F (2°C) inside the 

box. Set toward 1 for higher temperatures and set to a higher 

number for lower temperatures.

Evaporator Fan(s) Operation

Salad and mega top refrigerator units under 60" wide have 

one evaporator and one evaporator fan motor and blade. 

60", 64" and 72" wide units have one large evaporator and 

two fan motors and blades. Both motors rotate in the same 

direction and both have identical fan blades.

Important Information on 4427 Solid Top Models:

The unit is Energy Star Version II compliant. During normal 

operation the evaporator fan pulses independently of the 

compressor as dictated by the Danfoss Controller as follows:
1.  During the cooling mode, compressor and evaporator 

fan run simultaneously.

2.  During the compressor off mode, evaporator fan pulses 

three minutes on and three minutes off.

3.  During an actual defrost event other than the off-cycle 

defrost, compressor stays off but the evaporator fan runs 

continuously.

Cabinets with pans should be operated with pans 

in place. Operating the cabinet without all pans 

in place will lessen efficiency and may damage 

the cabinet.
Continuous opening and closing of the door will 

hamper the cabinet’s ability to maintain optimum 

refrigeration temperature.
Top section is not intended for overnight storage. 

Product should be removed from pans. Pans can 

remain in cabinet while empty.

Refrigerated Cabinet Operation

Flat Top Units except 4427 Models

Temperature Control Knob Access

Salad Top Units and 4427 Flat Top Models

Summary of Contents for 4427N

Page 1: ...829 Fax 989 773 3210 www delfield com Installation Operation Manual 4400 Series Compact Refrigerators 4500 Series Compact Freezers Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately 9294098 ...

Page 2: ...e Unless They Have Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety WARNING This Appliance Is Not To Be Played With Warning Do Not Clean With Water Jet WARNING Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This Appliance CAUTION Observe the following Minimum clearances must be maintained from all walls and comb...

Page 3: ...ing material until an inspection has been made or waived 9 Do not use forklift or pallet jack to move this equipment once it is removed from the pallet Doing so may cause equipment damage and void warranty Uncrating the Equipment First cut and remove the banding from around the crate Remove the front of the crate material use of some tools will be required If the unit is on legs remove the top of ...

Page 4: ...ield com This manual covers standard cabinets only If you have a custom cabinet consult the customer service department at 800 733 8829 2013 The Delfield Company All rights reserved Reproduction without written permission is prohibited Delfield is a registered trademark of The Delfield Company Introduction Regulatory Certifications Models are certified by National Sanitation Foundation NSF Underwr...

Page 5: ...9 5 15P 245 ST4427N one door 27 31 5 36 8 20 3 17 1 5 7 0 3 9 5 15P 223 STD4427N two drawer 27 31 5 36 8 20 1 5 7 0 3 9 5 15P 245 4432N one door 32 31 5 36 10 10 3 88 1 5 7 0 3 9 5 15P 245 D4432N two drawer 32 31 5 36 10 10 1 5 7 0 3 9 5 15P 293 ST4432N one door 32 31 5 36 10 10 3 88 1 5 7 0 3 9 5 15P 245 STD4432N two drawer 32 31 5 36 10 10 1 5 7 0 3 9 5 15P 293 4448N two door 48 31 5 36 16 00 5 ...

Page 6: ...5 15P 411 STD4460N 8 four drawer 60 31 5 36 20 20 8 1 2 11 12 5 15P 495 4464N 8 two door 64 31 5 36 21 60 7 76 8 1 2 11 12 5 15P 421 D4464N 8 four drawer 64 31 5 36 21 60 8 1 2 11 12 5 15P 522 4464N 12 two door 64 31 5 36 21 60 7 76 12 1 2 11 12 5 15P 421 D4464N 12 four drawer 64 31 5 36 21 60 12 1 2 11 12 5 15P 522 4464N 16 two door 64 31 5 36 21 60 7 76 16 1 2 11 12 5 15P 421 D4464N 16 four draw...

Page 7: ... 5 15P 495 ST4460N 18M two door 60 31 5 36 20 20 7 19 18 1 2 11 12 5 15P 411 STD4460N 18M four drawer 60 31 5 36 20 20 18 1 2 11 12 5 15P 495 4464N 12M two door 64 31 5 36 21 60 7 76 12 1 2 11 12 5 15P 421 D4464N 12M four drawer 64 31 5 36 21 60 12 1 2 11 12 5 15P 522 4464N 18M two door 64 31 5 36 21 60 7 76 18 1 2 11 12 5 15P 421 D4464N 18M four drawer 64 31 5 36 21 60 18 1 2 11 12 5 15P 522 4464...

Page 8: ... 60 31 5 34 25 20 20 8 1 2 11 12 5 15P 495 UC4460N 12 two door 60 31 5 34 25 20 20 7 19 12 1 2 11 12 5 15P 411 UCD4460N 12 four drawer 60 31 5 34 25 20 20 12 1 2 11 12 5 15P 495 UC4464N 8 two door 64 31 5 34 25 21 60 7 76 8 1 2 11 12 5 15P 421 UCD4464N 8 four drawer 64 31 5 34 25 21 60 8 1 2 11 12 5 15P 522 UC4464N 12 two door 64 31 5 34 25 21 60 7 76 12 1 2 11 12 5 15P 421 UCD4464N 12 four drawer...

Page 9: ... 31 5 34 25 20 20 7 19 18 1 2 11 12 5 15P 411 UCD4460N 18M four drawer 60 31 5 34 25 20 20 18 1 2 11 12 5 15P 495 UC4460N 24M two door 60 31 5 34 25 20 20 7 19 24 1 2 11 12 5 15P 411 UCD4460N 24M four drawer 60 31 5 34 25 20 20 24 1 2 11 12 5 15P 495 UC4464N 12M two door 64 31 5 34 25 21 60 7 76 12 1 2 11 12 5 15P 421 UCD4464N 12M four drawer 64 31 5 34 25 21 60 12 1 2 11 12 5 15P 522 UC4464N 18M ...

Page 10: ...15P 293lbs 133kg 4560N two door 60 152 4cm 31 5 80 0cm 36 91 4cm 16 90 7 19 1 3 14 0 12 0 5 15P 411lbs 186kg ST4560N two door 60 152 4cm 31 5 80 0cm 36 91 4cm 16 90 7 19 1 3 14 0 12 0 5 15P 411lbs 186kg ST prefix models have a 4 stainless steel backsplash Undercounter freezers Model Description L D Work H Volume Ft 3 Shelves Ft 2 H P Refg Charge Amp NEMA Plug Ship Weight UC4532N one door 32 81 3cm...

Page 11: ...n is the owner s and operator s responsibility Plumbing Self contained models are standard with a condensate evaporator If for some reason a cabinet does not have a condensate evaporator or the evaporator fails the cabinets drain must have an outlet to an appropriate drainage area or container Moisture collecting from improper drainage can createaslipperysurfaceonthefloorandahazard to employees It...

Page 12: ...upports Changing Pan Height If additional pan temperature cooling ability is desired especially in higher ambient temperature conditions and or if pan covers are open or off for extended time periods improvedcoolingofpanscanusuallybeachievedbyutilizing the lower position of the dual level pan guides When utilizing the lower position on a model with drawers only 4 deep pans can be used in the top W...

Page 13: ... located in rear of cabinet controls the temperatureinsidethebox Thefactorysettingforthecontrol is 4 5 and maintains about 34 F 1 C to 36 F 2 C inside the box Settoward1forhighertemperaturesandsettoahigher number for lower temperatures Evaporator Fan s Operation Salad and mega top refrigerator units under 60 wide have one evaporator and one evaporator fan motor and blade 60 64 and 72 wide units ha...

Page 14: ...en the controller enters the defrost mode the compressorisshutoffandwillremainoffuntiltheevaporator coiltemperatureexceeds41 Forthecontrollerreachesatime limitof50minutes Thedefrostcyclecanlastfromaminimum of 2 minutes to a maximum of 50 minutes Service Alert During normal operation the evaporator fan may cycle and or pulse independently of the compressor Consult the service manual or contact Tech...

Page 15: ...ol has completed initializing including the initial defrost cycle The temperature control will cycle the compressor and condenser fan motor and evaporator fan motor to maintain box temperature at the control setting Freezer Automatic Defrost The control also monitors compressor total running time and will enter a defrost cycle after total compressor running time is greater than 4 hours since the l...

Page 16: ...d other vegetables CLEANING THE CONDENSER COIL The condenser coil requires regular cleaning every 90 days recommended In some instances you may find a large amountofdebrisanddustorgreaseaccumulatedpriortothe 90 day time frame In these cases the condenser coil should be cleaned every 30 days Ifthebuilduponthecoilconsistsofonlylightdustanddebris thecondensercoilcanbecleanedwithasimplebrush Heavier d...

Page 17: ...sink with detergents and a soft bristle brush Drawers and tracks should be cleaned on a weekly basis Remove Drawers Pull the drawer box out until it stops Lift up on the drawer front andpullthedrawerboxcompletelyout Usingasoftbristlebrush clean the track on the bottom of the drawer box When finished it should be wiped clean of all food and debris Tracks The drawer box assembly must be removed Pull...

Page 18: ... G BLACK NEMA 5 15P Supply Cord and Plug furnished EVAPORATOR FAN TEMPERATURE CONTROL CONDENSING UNIT WHITE N HPS Wiring Diagram 4427 Flat Top Refrigerator Wiring Diagram All Remaining Flat Top Refrigerators 9294473 ...

Page 19: ...reezers NEMA 5 15P Supply Cord and Plug furnished L1 TEMPERATURE CONTROL HPS N 1 3 5 EVAPORATOR FANS POWER SWITCH Select models only CONDENSING UNIT Wiring Diagram Salad Mega Top Refrigerators Temperature Control Knob Access Power Switch Access 4460 4464 4472 Salad and Mega top models ...

Page 20: ...r with the service claim LABOR OF 1 HOUR IS ALLOWED TO REPLACE Thermostat Evaporator Condenser Fan Motor and Blade Hi limit Thermal Protector Switch Door Hinges Locks and Gaskets Compressor Start Components and Overload Protector LABOR OF 2 HOURS IS ALLOWED TO REPLACE Drawer Tracks Cartridges Locate Repair a Leak Defrost Heater LABOR OF 3 HOURS IS ALLOWED TO REPLACE Condenser or Evaporator Coil Ho...

Page 21: ...21 Compact Refrigerators Notes ...

Page 22: ...22 Delfield Notes ...

Page 23: ...23 Compact Refrigerators Notes ...

Page 24: ...u for choosing Delfield Help is a phone call away Help our team of professional courteous customer service reps by having your model number and serial number available at the time of your call 800 733 8829 Model ________________________ S N _______________________ Installation Date ________________ For a list of Delfield s authorized parts depots visit our website at www delfield com Register your...

Reviews: