200 and 300 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
INSTALLATION
Location
The refrigeration system has been factory tested
and should require no further adjustment during
installation.
For the most efficient refrigeration, be sure to provide
good air circulation inside and out.
Outside Cabinet:
Be sure that the unit has access
to ample air. Avoid hot corners and locations near
stoves and ovens.
Counter Cutouts
For installation provide a cutout in the counter as
shown (see illustration 1 or 2). The counter must be
sturdy enough to hold the combined weight up to 00
lbs. of the drop-in and the product stored inside.
The louver provided must be installed
in front of the condensing unit’s finned
coil (see illustration 3). A second
cutout must be made at the rear or
end of the equipment to allow air flow
through the unit. No louver is provided
for the second cutout. Any restriction
to the proper air flow, total or partial,
will void the compressor warranty.
225 or 227 DROP-IN
TYPICAL
COUNTER
CABINET
LOUVER
13.00" x 24.37"
33.0cm x 61.9cm
LOUVER CUTOUT SIZE
11.50" x 23.00"
29.2cm x 58.4cm
(typical installation)
NOTE:
A second cutout
(without louver) must
also be made to allow
proper air flow.
25.75"
65.4cm
28.0"
71.1cm
CUTOUT
.75"/1.9cm radius
1.00"/2.5cm (min.)
1.00"/2.5cm (min.)
COUNTERTOP
25.75"
65.4cm
14.62"
37.1cm
CUTOUT
.75"/1.9cm
radius
1.00"/2.5cm (min.)
1.00"/2.5cm (min.)
COUNTERTOP
Illustration 1. Model 225 cutout dimensions
Illustration 2. Model 227 cutout dimensions
Illustration 3. Models 225 & 227 louver installation
Electrical Connection
Refer to the amperage data on page 2, the serial tag,
your local code or the National Electrical Code to be
sure the unit is connected to the proper power source.
A protected circuit of the correct voltage and amperage
must be run for connection of the line cord.
If the unit does not operate after it is plugged in, check
the thermostat to see if it was inadvertently turned
OFF
during installation.
The unit must be disconnected from
the power source whenever performing
service or maintenance functions.