200 and 300 Series Service and Installation Manual

For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com

INSTALLATION

Location

The refrigeration system has been factory tested 
and should require no further adjustment during 
installation.  

For the most efficient refrigeration, be sure to provide 
good air circulation inside and out.

Outside Cabinet: 

Be sure that the unit has access 

to ample air.  Avoid hot corners and locations near 
stoves and ovens.

Counter Cutouts

For installation provide a cutout in the counter as 
shown (see illustration 1 or 2).  The counter must be 
sturdy enough to hold the combined weight up to 00 
lbs. of the drop-in and the product stored inside.

The louver provided must be installed 
in front of the condensing unit’s finned 
coil (see illustration 3).  A second 
cutout must be made at the rear or 
end of the equipment to allow air flow 
through the unit.  No louver is provided 
for the second cutout.  Any restriction 
to the proper air flow, total or partial, 
will void the compressor warranty.

225 or 227 DROP-IN

TYPICAL

COUNTER

CABINET

LOUVER

13.00" x 24.37"

33.0cm x 61.9cm

LOUVER CUTOUT SIZE

11.50" x 23.00"

29.2cm x 58.4cm

(typical installation)

NOTE:

 A second cutout 

(without louver) must 

also be made to allow 

proper air flow.

25.75"

65.4cm

28.0"

71.1cm

CUTOUT 

.75"/1.9cm radius 

1.00"/2.5cm (min.) 

1.00"/2.5cm (min.) 

COUNTERTOP

 

25.75"

65.4cm

14.62"

37.1cm

CUTOUT 

.75"/1.9cm 

radius 

1.00"/2.5cm (min.) 

1.00"/2.5cm (min.) 

COUNTERTOP

 

Illustration 1.  Model 225 cutout dimensions

Illustration 2.  Model 227 cutout dimensions

Illustration 3.  Models 225 & 227 louver installation

Electrical Connection

Refer to the amperage data on page 2, the serial tag, 
your local code or the National Electrical Code to be 
sure the unit is connected to the proper power source.  
A protected circuit of the correct voltage and amperage 
must be run for connection of the line cord.

If the unit does not operate after it is plugged in, check 
the thermostat to see if it was inadvertently turned 

OFF

 during installation.

The unit must be disconnected from 
the power source whenever performing 
service or maintenance functions.

Summary of Contents for 203

Page 1: ...l completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Drop In and Undercounter Products Effective APRIL 2003 IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS CAUTION ...

Page 2: ...d yet upon opening there is concealed damage to the equipment notify the carrier Notification should be made verbally as well as in written form 4 Request an inspection by the shipping company of the damaged equipment This should be done within 10 days from receipt of the equipment 5 Visually inspect the refrigeration package Be sure lines are secure and base is still intact 6 Freight carriers can...

Page 3: ...ction to the proper air flow total or partial will void the compressor warranty 225 or 227 DROP IN TYPICAL COUNTER CABINET LOUVER 13 00 x 24 37 33 0cm x 61 9cm LOUVER CUTOUT SIZE 11 50 x 23 00 29 2cm x 58 4cm typical installation NOTE A second cutout without louver must also be made to allow proper air flow 25 75 65 4cm 28 0 71 1cm C U T O U T 75 1 9cm radius 1 00 2 5cm min 1 00 2 5cm min COUNTERT...

Page 4: ...re such that the condenser is totally blocked in three months the frequency of cleaning should be increased Clean the condenser with a vacuum cleaner or stiff brush If extremely dirty a commercially available condenser cleaner may be required Defrosting must be done manually after 3 8 of ice accumulation The lid should be cleaned regularly with a soft cloth or sponge and solution of soap and water...

Page 5: ...7 225 Compressor 1 4 H P 404A 4 2183349 Harness power cord 5 3516047 Temperature control 6 3977986 Wire fan guard 7 GMK00203 Access cover 8 GMK000208 Comp stand 9 AMK00021 Fan motor bracket 10 2162691 Fan motor 11 3516172 Fan blade 12 GMK00207 Fan baffle 13 3516067 Condensing coil Purchase locally Capillary tube 031 i d 120 MK900086 Lid lock device 225 standard cover MV800013 Lid lock device 227 s...

Page 6: ...e 3234110 Cutout dimension 21 00 x 17 75 53 3cm x 45 1cm Parts list and cutout dimensions model 242 0761600 Parts list and cutout dimensions model 250 0762000 Basket Strainer 3234007 Faucet 3234076 Cutout dimensions 17 00 x 12 50 40 6cm x 31 8cm Basket strainer 3234007 Faucet 3234076 Glass filler 3234088 Drain 3234242 Grate 3978047 Removable lid 0360015 Lid handle 3234110 Cutout dimension 45 00 x ...

Page 7: ...ut dimensions model 307 0763300 Drain 3234242 Removable lid 0360015 Lid handle 3234110 Cutout dimensions 17 75 x 13 25 45 1cm x 33 7cm Glass filler 3234088 Grate 3978047 Cutout dimension 8 00 20 3cm diameter plus four 37 dia 1 0cm diameter holes arranged in a square 10 12 25 7cm on each side GND CONTROL POWER SUPPLY 115V 60 Hz 1Ø WHITE GREEN BLACK COMPRESSOR CONDENSER FAN wiring diagram models 225...

Page 8: ...PLACE Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Switch Microprocessor Control Fan Delay Defrost Termination Switch Water Level Sensor Probe Compressor Start Components and Overload Protector Door Hinges Locks and Gaskets Defrost Timer Condensate Element Th...

Page 9: ...TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part is requested prior to the arrival in the Delfield factory of the part claimed to be defective the Original Purchaser must accept delivery of the replacement part of a C O D basis with credit being issued ...

Page 10: ...fect its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to the condensing unit or refrigeration system shall void this warranty General Conditions Delfield shall not be liable in any manner for any ...

Page 11: ...200 and 300 Series Service and Installation Manual 11 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com notes ...

Page 12: ...oll free 1 800 272 7358 fax serves AR LA NM OK TX 7 Stove Parts Supply GCS Service 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA 12 Performance Refrigeration Parts 2200 Norcross Parkway Suite 210 Atlanta GA 30071 800 235 6516 770 446 6177 770 446 3157 FAX serves FL GA MS NC SC VA 13 Southeastern Restaurant Services 1816 West 26th Street Erie ...

Reviews: