background image

DM200_300 07/06

980 S. Isabella Rd., Mt. Pleasant, MI  48804-0470, U.S.A. • (989) 773-7981 or (800) 733-8821 • Fax (800) 669-0619 • www.delfield.com

Delfield reserves the right to make changes in design or specifications without prior notice.  2003 The Delfield Company.  All rights reserved. Printed in the U.S.A.

1336 Main Street

Buffalo, NY 14209

800.722.1252

716.884.7425

716. 884.0410 FAX

serves: CT, DC, DE, MA, MD, ME,

NH, NJ, NY, PA, RI, VA, VT, WV

3) Appliance Installation Service

15024 Staff Court

Gardena, CA 90248

1.800.531.1111

1.800.782.5747

Email: [email protected]

www.pacparts.com 

serves: AZ, CA, HI,  NV, OR

4) Pacific Coast Parts

2916 Sidco Drive

Nashville, TN 37204

615.726.0351

800.737.0351

615.259.4100 FAX

serves: TN, AL

14) T.M.A.

14450 Ewing Ave S. #100

Burnsville, MN 55306

800.422.2823

952.894.4427

952.894.2164 FAX

serves: IA, MN, MT, ND, SD, WI

5) Contract Ice

3909 St. Timothy Lane

St. Ann, MO 63074

800.972.7670

314.427.7477

314. 427.8190 FAX

serves: AR, IA, IL, KS,

KY, MO, NE, OK, TX, NM, LA

6) E.M.C.O. Sales & Distributors

2920 N.W. 109th Avenue

Miami, FL 33172

305 994.9994

305.994.9992 FAX

International parts depot

9) Global Parts and Supplies

2120 Solona St.

PO Box 14009

Fort Worth, TX 76117-0009

1.800.433.1804 toll free

1.800.272.7358 fax

serves: AR, LA, NM, OK, TX

7) Stove Parts Supply/GCS Service

9923 S.W. 178th St.

Vashon, WA 98070

888.872.2465

206-463-1772

206.463.4431 FAX

serves: AK, HI, ID, MT, OR, WA

12) Performance Refrigeration Parts

2200 Norcross Parkway, Suite 210

Atlanta, GA 30071

800.235.6516

770.446.6177

770.446.3157 FAX

serves: FL, GA, MS, NC, SC, VA

13) Southeastern Restaurant Services

1816 West 26th Street

Erie, PA 16508-1149

800.332.3732

814.456.3732

814.452.4843 FAX

serves: MD, NJ, OH, PA, VA, WV

2) A.I.S. Commercial Parts & Service

1177 Kamato Road

Mississauga, Ontario L4W1X4

800.427.6668

800.361.7745 FAX

serves: Canada

8) Garland Group

980 South Isabella Road

Mt. Pleasant, MI 48858

800.733.8829

989.773.7981

989.773.3210 FAX

custom parts direct from Delfield

1) The Delfield Company

44792 Helm

Plymouth, MI 48170

888.828.4454

734.451.2043

734.451.3215 FAX

serves: MI, IN, WI, OH

11) MicroDine, Inc.

3000 S. Wyandot

Englewood, CO 80110

(800) 624-2117

(303) 7618861 FAX

serves: AZ, CO, KS, NE, NM, OK, UT, WY

10) Hawkins Commercial Appl. Serv.

NORTH
AMERICA

4

4

12

9

10

1

11

7

6

5

14

3

13

8

2

12

Delfield has 14 conveniently located Parts Depots to 

ensure parts are handled promptly and accurately.

  

Delfield reserves the right to update or make changes

to this list without prior notice

Please call 1-800-733-8829 or check the web at www.delfield.com

for a list of the current Parts Depots.

AUTHORIZED PARTS DEPOTS

Summary of Contents for 203

Page 1: ...l completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Drop In and Undercounter Products Effective APRIL 2003 IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS CAUTION ...

Page 2: ...d yet upon opening there is concealed damage to the equipment notify the carrier Notification should be made verbally as well as in written form 4 Request an inspection by the shipping company of the damaged equipment This should be done within 10 days from receipt of the equipment 5 Visually inspect the refrigeration package Be sure lines are secure and base is still intact 6 Freight carriers can...

Page 3: ...ction to the proper air flow total or partial will void the compressor warranty 225 or 227 DROP IN TYPICAL COUNTER CABINET LOUVER 13 00 x 24 37 33 0cm x 61 9cm LOUVER CUTOUT SIZE 11 50 x 23 00 29 2cm x 58 4cm typical installation NOTE A second cutout without louver must also be made to allow proper air flow 25 75 65 4cm 28 0 71 1cm C U T O U T 75 1 9cm radius 1 00 2 5cm min 1 00 2 5cm min COUNTERT...

Page 4: ...re such that the condenser is totally blocked in three months the frequency of cleaning should be increased Clean the condenser with a vacuum cleaner or stiff brush If extremely dirty a commercially available condenser cleaner may be required Defrosting must be done manually after 3 8 of ice accumulation The lid should be cleaned regularly with a soft cloth or sponge and solution of soap and water...

Page 5: ...7 225 Compressor 1 4 H P 404A 4 2183349 Harness power cord 5 3516047 Temperature control 6 3977986 Wire fan guard 7 GMK00203 Access cover 8 GMK000208 Comp stand 9 AMK00021 Fan motor bracket 10 2162691 Fan motor 11 3516172 Fan blade 12 GMK00207 Fan baffle 13 3516067 Condensing coil Purchase locally Capillary tube 031 i d 120 MK900086 Lid lock device 225 standard cover MV800013 Lid lock device 227 s...

Page 6: ...e 3234110 Cutout dimension 21 00 x 17 75 53 3cm x 45 1cm Parts list and cutout dimensions model 242 0761600 Parts list and cutout dimensions model 250 0762000 Basket Strainer 3234007 Faucet 3234076 Cutout dimensions 17 00 x 12 50 40 6cm x 31 8cm Basket strainer 3234007 Faucet 3234076 Glass filler 3234088 Drain 3234242 Grate 3978047 Removable lid 0360015 Lid handle 3234110 Cutout dimension 45 00 x ...

Page 7: ...ut dimensions model 307 0763300 Drain 3234242 Removable lid 0360015 Lid handle 3234110 Cutout dimensions 17 75 x 13 25 45 1cm x 33 7cm Glass filler 3234088 Grate 3978047 Cutout dimension 8 00 20 3cm diameter plus four 37 dia 1 0cm diameter holes arranged in a square 10 12 25 7cm on each side GND CONTROL POWER SUPPLY 115V 60 Hz 1Ø WHITE GREEN BLACK COMPRESSOR CONDENSER FAN wiring diagram models 225...

Page 8: ...PLACE Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Switch Microprocessor Control Fan Delay Defrost Termination Switch Water Level Sensor Probe Compressor Start Components and Overload Protector Door Hinges Locks and Gaskets Defrost Timer Condensate Element Th...

Page 9: ...TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part is requested prior to the arrival in the Delfield factory of the part claimed to be defective the Original Purchaser must accept delivery of the replacement part of a C O D basis with credit being issued ...

Page 10: ...fect its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to the condensing unit or refrigeration system shall void this warranty General Conditions Delfield shall not be liable in any manner for any ...

Page 11: ...200 and 300 Series Service and Installation Manual 11 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com notes ...

Page 12: ...oll free 1 800 272 7358 fax serves AR LA NM OK TX 7 Stove Parts Supply GCS Service 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA 12 Performance Refrigeration Parts 2200 Norcross Parkway Suite 210 Atlanta GA 30071 800 235 6516 770 446 6177 770 446 3157 FAX serves FL GA MS NC SC VA 13 Southeastern Restaurant Services 1816 West 26th Street Erie ...

Reviews: