background image

200 and 300 Series Service and Installation Manual

For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com

10

ADDITIONAL FOUR YEAR PROTECTION PLAN 

 (for Motor-Compressor only)

 

 

Installation

Delfield Model# 

Serial # 

Date

In addition to the Standard One Year Warranty on the Motor-

Compressor contained in the above listed Delfield product (the 

“Unit”), The Delfield Company (“Delfield”) also agrees to repair, or 

exchange with similar or interchangeable parts in design and capacity 

at Delfield’s option, the defective Motor-Compressor contained in the 

Unit (the “Motor-Compressor), or any part thereof, for the Original 

Purchaser only, at any time during the four (4) years following the 

initial one (1) year period commencing on the date of installation for 

the Original Purchaser.  

Failure of the Original Purchaser to register 

the registration card containing the Original Purchasers name, 

address, date of installation, model number and serial number of 

the Unit containing the Motor-Compressor within 30 days from the 

date of installation shall void this warranty. 

 This additional warranty 

is only available if the Motor-Compressor is inoperative due to defects 

in material or factory workmanship, as determined by Delfield in 

its sole judgement and discretion.  The Original Purchaser shall be 

responsible for returning the defective Motor-Compressor to Delfield 

prepaid, F.O.B. at the address shown on the back cover of this manual.

The term “Original Purchaser” as used herein means that person, firm, 

association, or corporation for whom the Unit was originally installed. 

The term “Motor-Compressor” as used herein does not include unit 

base, air or water cooled condenser, receiver, electrical accessories 

such as relay, capacitors, refrigerant controls, or condenser fan/motor 

assembly.  This warranty does not cover labor charges incidental to 

the replacement of parts.   This warranty further does not include 

any equipment to which said condensing unit is connected, such as 

cooling coils, temperature controls or refrigerant metering devices.  

This warranty shall be void if the Motor-Compressor, in Delfield’s 

sole judgement, has been subjected to misuse, neglect, alteration 

or accident, operated contrary to the recommendations specified 

by the Unit manufacturer, repaired or altered by anyone other than 

Delfield in any way so as, in Delfield’s sole judgment, to affect its 

quality or efficiency or if the serial number has been altered, defaced 

or removed.  This Warranty does not apply to a Motor-Compressor in 

any Unit that has been moved from the location where it was originally 

installed.  The addition of methyl chloride to the condensing unit or 

refrigeration system shall void this warranty.

general Conditions

Delfield shall not be liable in any manner for any default or delay 

in performance hereunder caused by or resulting from any 

contingency beyond Delfield’s control, including, but not limited 

to, war, governmental restrictions or restraints, strike, lockouts, 

injunctions, fire, flood, acts of nature, short or reduced supply 

of raw materials, or discontinuance of any part or the Motor-

Compressor by the unit manufacturer.

Replacement of a defective Motor-Compressor is limited to one (1) 

Motor-Compressor by us during the four (4) year period.  Delfield 

shall replace the Motor-Compressor at no charge.

This warranty does not give the Original Purchaser of the Motor-

Compressor the right to purchase a complete replacement Motor-

Compressor of the same make or of another make.  It further does 

not permit the replacement to be made with a Motor-Compressor 

of another kind unless authorized by Delfield.  In the event Delfield 

authorizes the Original Purchaser to purchase a replacement 

Motor-Compressor locally, only the wholesale cost of the Motor-

Compressor is refundable.

Expressly excluded from this warranty are damages resulting from 

spoilage of goods.

Except as provided in any applicable Standard One Year Limited 

Warranty or applicable Service Labor Contract, the foregoing 

is exclusive and in lieu of all other warranties, whether written 

or oral, express or implied.  This Warranty supersedes and 

excludes any prior oral or written representations or warranties.  

Delfield expressly disclaims any implied warranties of 

merchantability, fitness for a particular purpose or compliance 

with any law, treaty, rule or regulation relating to the Motor-

Compressor, and the full liability of Delfield for any breach of this 

warranty, will be as provided in this warranty.

Other than any applicable Delfield Standard One year Limited 

Warranty, this Delfield Additional Four Year Protection Plan and any 

applicable Delfield Service Labor Contract, the Original Purchaser 

agrees and acknowledges that no other warranties are offered or 

provided in connection with or for the Motor-Compressor or any 

part thereof.

In no event will Delfield be liable for special, incidental or 

consequential damages, or for damages in the nature of penalties.

Summary of Contents for 203

Page 1: ...l completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Drop In and Undercounter Products Effective APRIL 2003 IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS CAUTION ...

Page 2: ...d yet upon opening there is concealed damage to the equipment notify the carrier Notification should be made verbally as well as in written form 4 Request an inspection by the shipping company of the damaged equipment This should be done within 10 days from receipt of the equipment 5 Visually inspect the refrigeration package Be sure lines are secure and base is still intact 6 Freight carriers can...

Page 3: ...ction to the proper air flow total or partial will void the compressor warranty 225 or 227 DROP IN TYPICAL COUNTER CABINET LOUVER 13 00 x 24 37 33 0cm x 61 9cm LOUVER CUTOUT SIZE 11 50 x 23 00 29 2cm x 58 4cm typical installation NOTE A second cutout without louver must also be made to allow proper air flow 25 75 65 4cm 28 0 71 1cm C U T O U T 75 1 9cm radius 1 00 2 5cm min 1 00 2 5cm min COUNTERT...

Page 4: ...re such that the condenser is totally blocked in three months the frequency of cleaning should be increased Clean the condenser with a vacuum cleaner or stiff brush If extremely dirty a commercially available condenser cleaner may be required Defrosting must be done manually after 3 8 of ice accumulation The lid should be cleaned regularly with a soft cloth or sponge and solution of soap and water...

Page 5: ...7 225 Compressor 1 4 H P 404A 4 2183349 Harness power cord 5 3516047 Temperature control 6 3977986 Wire fan guard 7 GMK00203 Access cover 8 GMK000208 Comp stand 9 AMK00021 Fan motor bracket 10 2162691 Fan motor 11 3516172 Fan blade 12 GMK00207 Fan baffle 13 3516067 Condensing coil Purchase locally Capillary tube 031 i d 120 MK900086 Lid lock device 225 standard cover MV800013 Lid lock device 227 s...

Page 6: ...e 3234110 Cutout dimension 21 00 x 17 75 53 3cm x 45 1cm Parts list and cutout dimensions model 242 0761600 Parts list and cutout dimensions model 250 0762000 Basket Strainer 3234007 Faucet 3234076 Cutout dimensions 17 00 x 12 50 40 6cm x 31 8cm Basket strainer 3234007 Faucet 3234076 Glass filler 3234088 Drain 3234242 Grate 3978047 Removable lid 0360015 Lid handle 3234110 Cutout dimension 45 00 x ...

Page 7: ...ut dimensions model 307 0763300 Drain 3234242 Removable lid 0360015 Lid handle 3234110 Cutout dimensions 17 75 x 13 25 45 1cm x 33 7cm Glass filler 3234088 Grate 3978047 Cutout dimension 8 00 20 3cm diameter plus four 37 dia 1 0cm diameter holes arranged in a square 10 12 25 7cm on each side GND CONTROL POWER SUPPLY 115V 60 Hz 1Ø WHITE GREEN BLACK COMPRESSOR CONDENSER FAN wiring diagram models 225...

Page 8: ...PLACE Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Switch Microprocessor Control Fan Delay Defrost Termination Switch Water Level Sensor Probe Compressor Start Components and Overload Protector Door Hinges Locks and Gaskets Defrost Timer Condensate Element Th...

Page 9: ...TO CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part is requested prior to the arrival in the Delfield factory of the part claimed to be defective the Original Purchaser must accept delivery of the replacement part of a C O D basis with credit being issued ...

Page 10: ...fect its quality or efficiency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to the condensing unit or refrigeration system shall void this warranty General Conditions Delfield shall not be liable in any manner for any ...

Page 11: ...200 and 300 Series Service and Installation Manual 11 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com notes ...

Page 12: ...oll free 1 800 272 7358 fax serves AR LA NM OK TX 7 Stove Parts Supply GCS Service 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA 12 Performance Refrigeration Parts 2200 Norcross Parkway Suite 210 Atlanta GA 30071 800 235 6516 770 446 6177 770 446 3157 FAX serves FL GA MS NC SC VA 13 Southeastern Restaurant Services 1816 West 26th Street Erie ...

Reviews: